An Evaluation of the Reliability of Manual Landmark Identification on 3D Segmented Wrists
Journal of Bone and Joint Surgery · 2024
DOI: 10.2106/jbjs.23.00173 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Bone and Joint Surgery, 2024. Verfasst von Rémy Winter und 6 weiteren Autor:innen. Beteiligte Einrichtung: Unité de Recherche Clinique Côte d'Azur (UR2CA), Université Côte d'Azur, Nice, France. Hauptthemen laut MEDLINE: Lunate Bone, Radius Fractures. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 18 Literaturangaben.
Abstract (Originalsprache)
Background
Three-dimensional (3D) preoperative planning is increasingly used in orthopaedic surgery. Two-dimensional (2D) characterization of distal radial deformities remains inaccurate, and 3D planning requires a reliable reference frame at the wrist. We aim to evaluate the reliability of the determination of anatomical points placed manually on 3D models of the radius to determine which of those points allow reliable morphometric measurements.
Methods
Twenty-three radial scans were reconstructed in 3D. Five operators specialized in the upper limb manually positioned 8 anatomical points on each model. One of the operators repeated the operation 6 times. The anatomical points were based on previously published 3D models used for radial inclination and dorsopalmar tilt measurements. The repeatability and reproducibility of the measurements derived using this manual landmarking were calculated using different measurement methods based on the identified points. An error of ≤2° was considered clinically acceptable.
Results
This study of intraobserver and interobserver variability of the anatomic points allowed us to determine the least variable and most accurately defined points. The middle of the ulnar border of the radius, the radial styloid, and the midpoint of the ulnar incisura of the radius were the least variable. The palmar and dorsal ends of the ridge delineating the scaphoid and lunate facets were the most variable. Only 1 of the radial inclination measurement methods was clinically acceptable; the others had a repeatability and reproducibility limit of >2°, making those measurements clinically unacceptable.
Conclusions
The use of isolated points seems insufficient for the development of a wrist reference frame, especially for the purpose of measuring dorsopalmar tilt. If one concurs that an error of 2° is unacceptable for all distal radial measurements, then clinicians should avoid using 3D landmarked points, due to their unreliability, except for radial inclination measured using the radial styloid and the midpoint of the ulnar edge of the radius. A characterization of the wrist using 3D shapes that fit the articular surface of the radius should be considered. Level of Evidence: Diagnostic Level III . See Instructions for Authors for a complete description of levels of evidence.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Unité de Recherche Clinique Côte d'Azur (UR2CA), Université Côte d'Azur, Nice, France.
- Hôpital Pasteur 2, Centre Hospitalier Universitaire de Nice, Nice, France.
- Newclip Technics, Haute-Goulaine, France.
- Fournitures Hospitalieres Industrie, Quimper, France.
- Institut des Sciences Mouvement, Aix-Marseille University, French National Centre for Scientific Research, Marseille, France.
ORCID-Profile: Rémy Winter, Arnaud Citarel, Patrick Chabrand, Audrey Chenel, Nicolas Bronsard, Thibault Poujade, Marc-Olivier Gauci
Zitieren
APA
Winter, R., Citarel, A., Chabrand, P., Chenel, A., Bronsard, N., Poujade, T., & Gauci, M. O. (2024). An Evaluation of the Reliability of Manual Landmark Identification on 3D Segmented Wrists. Journal of Bone and Joint Surgery. https://doi.org/10.2106/jbjs.23.00173
Vancouver
Winter R, Citarel A, Chabrand P, Chenel A, Bronsard N, Poujade T, et al. An Evaluation of the Reliability of Manual Landmark Identification on 3D Segmented Wrists. Journal of Bone and Joint Surgery. 2024. doi:10.2106/jbjs.23.00173
BibTeX
@article{Winter2024,
author = {Winter, Rémy and Citarel, Arnaud and Chabrand, Patrick and Chenel, Audrey and Bronsard, Nicolas and Poujade, Thibault and Gauci, Marc-Olivier},
title = {An Evaluation of the Reliability of Manual Landmark Identification on 3D Segmented Wrists},
journal = {Journal of Bone and Joint Surgery},
year = {2024},
doi = {10.2106/jbjs.23.00173}
}
EUVIMED