EUVIMEDEUVIMED entdecken
Crossref

Use of volar distal radius plate dorsally for wrist arthrodesis in patients with upper limb spasticity: A retrospective review

Rahul Bamal, Ramy Sultan, Laura Cappuyns, Zahid Hassan, Paul McArthur

Journal of Plastic, Reconstructive & Aesthetic Surgery · 2023

DOI: 10.1016/j.bjps.2023.05.005 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Plastic, Reconstructive & Aesthetic Surgery, 2023. Verfasst von Rahul Bamal und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Plastic Surgery, Whiston Hospital, Prescot L35 5DR, UK; Department of Plastic Surgery, Alder Hey Children's Hospital, Liverpool L15 5AB…. Hauptthemen laut MEDLINE: Radius, Radius Fractures. Die Arbeit nennt 15 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Standard wrist arthrodesis implants are generally designed for adult joints with arthritis. They are often too big for patients with limb spasticity who generally tend to have osteopenic and smaller bones for their age, resulting in high complication rates. We previously described the novel use of volar distal radius variable-angle locking plate (APTUS® Wrist distal radius system 2.5, Medartis AG, Basel, Switzerland) on the dorsum for wrist arthrodesis in patients with limb spasticity. This study aimed to further establish the use of the implant by reporting the outcomes in cohort A (nondistal radius plate) and cohort B (distal radius plate cohort). Patient-reported outcome measures were used to assess the primary outcome, whereas secondary outcomes included implant-related complications and improvement in wrist position and fusion rates. A total of 17 wrist arthrodesis procedures were performed over a period of 4 years in 15 patients for wrist deformity secondary to limb spasticity. There were no complaints of implant prominence, implant or tendon irritation, metacarpal prominence, or extension requiring further treatment in cohort B. Cohort A had a high implant removal rate that is comparable to the published literature. Both groups reported significant improvement in hygiene and wrist position but neither group had any appreciable gain in function. Volar distal radius variable-angle locking plates appear to be safe and have superior patient acceptability and low complication rates when used dorsally for wrist arthrodesis in patients with upper limb spasticity. Comparable overall satisfaction rates in cohort B were reported in relation to the literature and the cohort A in this study.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RadiusRadius FracturesAdultHumansWristRetrospective StudiesWrist JointPostoperative ComplicationsFracture Fixation, InternalArthrodesisBone PlatesTreatment OutcomeRange of Motion, Articular

Stichwörter der Autor:innen

Cerebral palsyDistal Radius PlateLimb spasticityWrist arthrodesisWrist fusion

Autor:innen und Institutionen

  • Department of Plastic Surgery, Whiston Hospital, Prescot L35 5DR, UK; Department of Plastic Surgery, Alder Hey Children's Hospital, Liverpool L15 5AB, UK; School of Medicine & Dentistry, Griffith University, Gold Coast,…
  • Department of Plastic Surgery, Whiston Hospital, Prescot L35 5DR, UK.
  • Department of Plastic Surgery, Whiston Hospital, Prescot L35 5DR, UK; Department of Plastic Surgery, Alder Hey Children's Hospital, Liverpool L15 5AB, UK.

Zitieren

APA

Bamal, R., Sultan, R., Cappuyns, L., Hassan, Z., & McArthur, P. (2023). Use of volar distal radius plate dorsally for wrist arthrodesis in patients with upper limb spasticity: A retrospective review. Journal of Plastic, Reconstructive & Aesthetic Surgery. https://doi.org/10.1016/j.bjps.2023.05.005

Vancouver

Bamal R, Sultan R, Cappuyns L, Hassan Z, McArthur P. Use of volar distal radius plate dorsally for wrist arthrodesis in patients with upper limb spasticity: A retrospective review. Journal of Plastic, Reconstructive & Aesthetic Surgery. 2023. doi:10.1016/j.bjps.2023.05.005

BibTeX
@article{Bamal2023,
  author = {Bamal, Rahul and Sultan, Ramy and Cappuyns, Laura and Hassan, Zahid and McArthur, Paul},
  title = {Use of volar distal radius plate dorsally for wrist arthrodesis in patients with upper limb spasticity: A retrospective review},
  journal = {Journal of Plastic, Reconstructive & Aesthetic Surgery},
  year = {2023},
  doi = {10.1016/j.bjps.2023.05.005}
}
Kostenlos starten →