Measurement of Loudness Discomfort Levels as a Test for Hyperacusis: Test-Retest Reliability and Its Clinical Value
Clinical and Experimental Otorhinolaryngology · 01.02.2022 · 15 (1) · 84-90
DOI: 10.21053/ceo.2021.00318 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical and Experimental Otorhinolaryngology, erschienen am 01.02.2022. Verfasst von Jaclyn Leigh Vidal und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otorhinolaryngology-Head and Neck Surgery, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Kor…. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 3.0). Gefördert von: National Research Foundation of Korea, Ministry of Education.
Abstract (Originalsprache)
Objectives
The aims of this study were to investigate the test-retest reliability of measurements of loudness discomfort levels (LDLs), to suggest cut-off values for diagnosing patients with hyperacusis, and to evaluate the clinical value of-LDL measurements as a test for monitoring hyperacusis.
Methods
For the test-retest reliability of LDL measurements (study 1), a total of 68 patients who sought consultations at our clinic were subcategorized into four groups: patients with tinnitus (group 1), tinnitus and hearing loss (group 2), hyperacusis (group 3), and normal controls (group 4). Inter-hour and inter-day test-retest reliability values using different stimuli were investigated. For study 2, the clinical value of LDL measurements using pure tone stimuli was analyzed by comparing changes after sound generator use in patients with hyperacusis.
Results
In study 1, the group 3 patients showed significantly lower LDLs than the other groups. High test-retest reliability of LDL tests was demonstrated, regardless of the type of stimulus used. The cut-off values for screening patients with hyperacusis were 90 dB HL using pure tone stimuli and 62 dB HL using white-band noise stimuli. In study 2, significantly increased LDLs were correlated with improved symptoms and improved scores on tinnitus questionnaires after sound generator use, indicating that LDL measurement is a reliable test for monitoring hyperacusis during an intervention.
Conclusion
LDL measurement is a reliable diagnostic tool to reflect the condition of hyperacusis, especially during the course of treatment.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Otorhinolaryngology-Head and Neck Surgery, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea.
- Department of Otorhinolaryngology-Head and Neck Surgery, Dr. Paulino J. Garcia Memorial Research and Medical Center, Nueva Ecija, Philippines.
- Department of Otorhinolaryngology-Head and Neck Surgery, St. Luke's Medical Center, Quezon City, Philippines.
Förderung
- National Research Foundation of Korea
- Ministry of Education
Zitieren
APA
Vidal, J. L., Park, J. M., Han, J. S., Alshaikh, H., & Park, S. N. (2022). Measurement of Loudness Discomfort Levels as a Test for Hyperacusis: Test-Retest Reliability and Its Clinical Value. Clinical and Experimental Otorhinolaryngology, 15(1), 84-90. https://doi.org/10.21053/ceo.2021.00318
Vancouver
Vidal JL, Park JM, Han JS, Alshaikh H, Park SN. Measurement of Loudness Discomfort Levels as a Test for Hyperacusis: Test-Retest Reliability and Its Clinical Value. Clinical and Experimental Otorhinolaryngology. 2022;15(1):84-90. doi:10.21053/ceo.2021.00318
BibTeX
@article{Vidal2022,
author = {Vidal, Jaclyn Leigh and Park, Jung Mee and Han, Jae Sang and Alshaikh, Hamzah and Park, Shi Nae},
title = {Measurement of Loudness Discomfort Levels as a Test for Hyperacusis: Test-Retest Reliability and Its Clinical Value},
journal = {Clinical and Experimental Otorhinolaryngology},
year = {2022},
volume = {15},
number = {1},
pages = {84--90},
doi = {10.21053/ceo.2021.00318}
}
EUVIMED