EUVIMEDEUVIMED entdecken
Open Access

Upper trapezius muscle elasticity in cervical myofascial pain syndrome measured using real-time ultrasound shear-wave elastography

Chang-Juan Hao, Xiao-Yan Kang, Chun-Song Kang, Ting-Ting Li, Jian-Zhong Huo, Qian Xu, Wen-Li Xiao, Zhe-Xia Zhao, Xing-Hua Ji, Quan-Bin Zhang

Quantitative Imaging in Medicine and Surgery · 2023-08 · 13 (8) · 5168-5181

DOI: 10.21037/qims-22-797 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Quantitative Imaging in Medicine and Surgery, 2023-08. Verfasst von Chang-Juan Hao und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ultrasound, Third Hospital of Shanxi Medical University, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Shanxi Tongji Hos…. Die Arbeit wurde bisher 19-mal zitiert (Crossref). Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Myofascial pain syndrome (MPS) is a common cause of neck pain, which is a global public health problem. Because MPS does not present morphological changes within lesioned muscles, there are no imaging diagnostic criteria for this condition. In this study, we evaluate elasticity changes in upper trapezius muscles most frequently involved in cervical MPS using real-time ultrasound shear-wave elastography, and we examine their potential diagnostic value.

Methods

We consecutively enrolled 109 right posterior neck pain patients for this prospective study. Of these, 51 were diagnosed with MPS and 58 with non-MPS in the right side of their neck. Among MPS patients, 19 fell into the 1-3 range (mild pain) for pain scores on the visual analog scale (VAS), 25 fell into the 4-6 range (moderate pain), and 7 into the 7-10 range (severe pain). MPS was diagnosed by two independent clinicians using the diagnostic criteria proposed by Simons et al. Using real-time ultrasound shear-wave elastography, we measured right trapezius mean shear-wave velocity (SWVmean). The midpoint of the line between the foramen magnum and the end of the right acromion served as measuring point. Regions of interest were scaled to span 0-8.0 m/s.

Results

Trapezius SWVmean was significantly higher in MPS patients compared with non-MPS patients (P

Schlagwörter

Stichwörter der Autor:innen

Myofascial pain syndrome (MPS)cervicalelastographyreal-time ultrasound shear-wave elastographyupper trapezius muscle

Autor:innen und Institutionen

  • Department of Ultrasound, Third Hospital of Shanxi Medical University, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Shanxi Tongji Hospital, Taiyuan, China.
  • Department of Orthopedics, Central Hospital in Taiyuan, Taiyuan, China.
  • Business Division, Hologic (Shanghai) Medical Supplies Co. Ltd., Shanghai, China.
  • Department of Orthopedics, Third Hospital of Shanxi Medical University, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Shanxi Tongji Hospital, Taiyuan, China.
  • Department of Ultrasound, Sixth Hospital of Shanxi Medical University, Taiyuan, China.

Zitieren

APA

Hao, C. J., Kang, X. Y., Kang, C. S., Li, T. T., Huo, J. Z., Xu, Q., Xiao, W. L., Zhao, Z. X., Ji, X. H., & Zhang, Q. B. (2023). Upper trapezius muscle elasticity in cervical myofascial pain syndrome measured using real-time ultrasound shear-wave elastography. Quantitative Imaging in Medicine and Surgery, 13(8), 5168-5181. https://doi.org/10.21037/qims-22-797

Vancouver

Hao CJ, Kang XY, Kang CS, Li TT, Huo JZ, Xu Q, et al. Upper trapezius muscle elasticity in cervical myofascial pain syndrome measured using real-time ultrasound shear-wave elastography. Quantitative Imaging in Medicine and Surgery. 2023;13(8):5168-5181. doi:10.21037/qims-22-797

BibTeX
@article{Hao2023,
  author = {Hao, Chang-Juan and Kang, Xiao-Yan and Kang, Chun-Song and Li, Ting-Ting and Huo, Jian-Zhong and Xu, Qian and Xiao, Wen-Li and Zhao, Zhe-Xia and Ji, Xing-Hua and Zhang, Quan-Bin},
  title = {Upper trapezius muscle elasticity in cervical myofascial pain syndrome measured using real-time ultrasound shear-wave elastography},
  journal = {Quantitative Imaging in Medicine and Surgery},
  year = {2023},
  volume = {13},
  number = {8},
  pages = {5168--5181},
  doi = {10.21037/qims-22-797}
}
Kostenlos starten →