Upper trapezius muscle elasticity in cervical myofascial pain syndrome measured using real-time ultrasound shear-wave elastography
Quantitative Imaging in Medicine and Surgery · 2023-08 · 13 (8) · 5168-5181
DOI: 10.21037/qims-22-797 ↗Kurz gefasst
Fachartikel in der Zeitschrift Quantitative Imaging in Medicine and Surgery, 2023-08. Verfasst von Chang-Juan Hao und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ultrasound, Third Hospital of Shanxi Medical University, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Shanxi Tongji Hos…. Die Arbeit wurde bisher 19-mal zitiert (Crossref). Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background
Myofascial pain syndrome (MPS) is a common cause of neck pain, which is a global public health problem. Because MPS does not present morphological changes within lesioned muscles, there are no imaging diagnostic criteria for this condition. In this study, we evaluate elasticity changes in upper trapezius muscles most frequently involved in cervical MPS using real-time ultrasound shear-wave elastography, and we examine their potential diagnostic value.
Methods
We consecutively enrolled 109 right posterior neck pain patients for this prospective study. Of these, 51 were diagnosed with MPS and 58 with non-MPS in the right side of their neck. Among MPS patients, 19 fell into the 1-3 range (mild pain) for pain scores on the visual analog scale (VAS), 25 fell into the 4-6 range (moderate pain), and 7 into the 7-10 range (severe pain). MPS was diagnosed by two independent clinicians using the diagnostic criteria proposed by Simons et al. Using real-time ultrasound shear-wave elastography, we measured right trapezius mean shear-wave velocity (SWVmean). The midpoint of the line between the foramen magnum and the end of the right acromion served as measuring point. Regions of interest were scaled to span 0-8.0 m/s.
Results
Trapezius SWVmean was significantly higher in MPS patients compared with non-MPS patients (P
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ultrasound, Third Hospital of Shanxi Medical University, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Shanxi Tongji Hospital, Taiyuan, China.
- Department of Orthopedics, Central Hospital in Taiyuan, Taiyuan, China.
- Business Division, Hologic (Shanghai) Medical Supplies Co. Ltd., Shanghai, China.
- Department of Orthopedics, Third Hospital of Shanxi Medical University, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Shanxi Tongji Hospital, Taiyuan, China.
- Department of Ultrasound, Sixth Hospital of Shanxi Medical University, Taiyuan, China.
Zitieren
APA
Hao, C. J., Kang, X. Y., Kang, C. S., Li, T. T., Huo, J. Z., Xu, Q., Xiao, W. L., Zhao, Z. X., Ji, X. H., & Zhang, Q. B. (2023). Upper trapezius muscle elasticity in cervical myofascial pain syndrome measured using real-time ultrasound shear-wave elastography. Quantitative Imaging in Medicine and Surgery, 13(8), 5168-5181. https://doi.org/10.21037/qims-22-797
Vancouver
Hao CJ, Kang XY, Kang CS, Li TT, Huo JZ, Xu Q, et al. Upper trapezius muscle elasticity in cervical myofascial pain syndrome measured using real-time ultrasound shear-wave elastography. Quantitative Imaging in Medicine and Surgery. 2023;13(8):5168-5181. doi:10.21037/qims-22-797
BibTeX
@article{Hao2023,
author = {Hao, Chang-Juan and Kang, Xiao-Yan and Kang, Chun-Song and Li, Ting-Ting and Huo, Jian-Zhong and Xu, Qian and Xiao, Wen-Li and Zhao, Zhe-Xia and Ji, Xing-Hua and Zhang, Quan-Bin},
title = {Upper trapezius muscle elasticity in cervical myofascial pain syndrome measured using real-time ultrasound shear-wave elastography},
journal = {Quantitative Imaging in Medicine and Surgery},
year = {2023},
volume = {13},
number = {8},
pages = {5168--5181},
doi = {10.21037/qims-22-797}
}
EUVIMED