Shear-wave ultrasound elastography for tissue-specific quantification of radiation-induced cervical fibrosis
Physics and Imaging in Radiation Oncology · 2026-05 · 39 · 101005
DOI: 10.1016/j.phro.2026.101005 ↗Kurz gefasst
Fachartikel in der Zeitschrift Physics and Imaging in Radiation Oncology, 2026-05. Verfasst von Hendrik Dapper und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radio-Oncology, Klinikum rechts der Isar, Technical University of Munich, Ismaninger Str. 22, 81675 Munich, Germany. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background and purpose: Radiation-induced cervical fibrosis is a common late effect following radiotherapy for head and neck cancer, potentially leading to reduced tissue compliance and functional impairment. Objective assessment, however, remains challenging in clinical practice. Therefore, this study aimed to evaluate the feasibility of shear-wave ultrasound elastography (SWE) for quantitative, tissue-specific assessment of radiation-induced cervical fibrosis. Materials and methods: Sixteen patients after bilateral cervical lymphatic irradiation were compared with sixteen age-, sex-, and body mass index-matched controls without prior head and neck irradiation. SWE was used to quantify stiffness of muscle, fascia, and subcutaneous tissue of the sternocleidomastoid muscle. Ultrasound-based thickness measurements and assessment of cervical range of motion were additionally performed.
Results
Mean muscle stiffness was significantly higher in irradiated patients compared with controls (left: 46.98 vs. 28.10 kPa; right: 46.75 vs. 21.52 kPa). Comparable increases were observed in the fascia (left: 46.41 vs. 25.47 kPa; right: 44.28 vs. 22.69 kPa), whereas differences in subcutaneous tissue were less pronounced. Muscle and skin thickness were significantly reduced after radiotherapy. Cervical range of motion did not differ significantly between groups, although a non-significant reduction of approximately 5° in cervical rotation was observed. Negative correlations between muscle stiffness and cervical range of motion were observed but did not reach statistical significance.
Conclusion
Shear-wave elastography enables reliable, tissue-specific quantification of radiation-induced cervical fibrosis, predominantly affecting muscle and fascia. Despite increased tissue stiffness and reduced thickness, cervical range of motion remained largely preserved, suggesting a dissociation between structural tissue alterations and functional impairment.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radio-Oncology, Klinikum rechts der Isar, Technical University of Munich, Ismaninger Str. 22, 81675 Munich, Germany.
- Department of Radiation Oncology, Cyberknife and Radiation Therapy, Faculty of Medicine and University Hospital of Cologne, University of Cologne, Kerpener St. 62, 50937 Cologne, Germany.
- German Cancer Consortium (DKTK), Partner Site Munich, a Partnership between DKFZ and University Hospital Klinikum Rechts der Isar, 81675 Munich, Germany.
- Department of Radiation Sciences, Germany, Institute of Innovative Radiotherapy, Helmholtz Zentrum München, 85764 Oberschleißheim, Germany.
- Department of Neurology, Klinikum rechts der Isar, Technical University of Munich, Ismaninger Str. 22, 81675 Munich, Germany.
- Conservative and Rehabilitative Orthopaedics, TUM School of Medicine and Health, Technical University of Munich, Campus D, Am Olympiacampus 11, 80809 Munich, Germany.
Zitieren
APA
Dapper, H., Waltenberger, M., Pigorsch, S. U., Combs, S. E., Bauermeister, K., & Bauermeister, W. (2026). Shear-wave ultrasound elastography for tissue-specific quantification of radiation-induced cervical fibrosis. Physics and Imaging in Radiation Oncology, 39, 101005. https://doi.org/10.1016/j.phro.2026.101005
Vancouver
Dapper H, Waltenberger M, Pigorsch SU, Combs SE, Bauermeister K, Bauermeister W. Shear-wave ultrasound elastography for tissue-specific quantification of radiation-induced cervical fibrosis. Physics and Imaging in Radiation Oncology. 2026;39:101005. doi:10.1016/j.phro.2026.101005
BibTeX
@article{Dapper2026,
author = {Dapper, Hendrik and Waltenberger, Maria and Pigorsch, Steffi U and Combs, Stephanie E and Bauermeister, Katharina and Bauermeister, Wolfgang},
title = {Shear-wave ultrasound elastography for tissue-specific quantification of radiation-induced cervical fibrosis},
journal = {Physics and Imaging in Radiation Oncology},
year = {2026},
volume = {39},
pages = {101005},
doi = {10.1016/j.phro.2026.101005}
}
EUVIMED