Three-dimensional pseudo-continuous arterial spin labeling magnetic resonance imaging: an effective imaging technique for early-stage kidney injury in patients with type 2 diabetes
Quantitative Imaging in Medicine and Surgery · 2026-04 · 16 (4) · 299-299
DOI: 10.21037/qims-2025-1776 ↗Kurz gefasst
Fachartikel in der Zeitschrift Quantitative Imaging in Medicine and Surgery, 2026-04. Verfasst von Wenli Fang und 7 weiteren Autor:innen. Beteiligte Einrichtung: The Second School of Clinical Medicine, Hangzhou Normal University, Hangzhou, China. Die Arbeit wurde bisher 3-mal zitiert (Crossref). Der Volltext ist frei in PubMed Central verfügbar.
Themen: Diabetes mellitus
Abstract (Originalsprache)
Background
Functional biomarkers cannot currently detect hemodynamic impairment in patients with early-stage kidney injury and type 2 diabetes mellitus (T2DM). This study evaluated the utility of three-dimensional pseudo-continuous arterial spin labeling (3D-pCASL) magnetic resonance imaging (MRI) in quantifying stage-specific renal blood flow (RBF) alterations in patients with T2DM.
Methods
A total of 33 patients with T2DM, who were divided into normoalbuminuria (NAU; n=11), microalbuminuria (MAU; n=13), and diabetic kidney disease (DKD; n=9), along with 15 healthy volunteers (HVs), were recruited. All participants underwent renal contrast-enhanced MRI and 3D-pCASL examinations on a 3.0-T scanner. Two experienced radiologists independently segmented the kidneys based on the postcontrast cortical phase images and measured the cortical RBF. The cortical RBF values across the four groups were compared via one-way analysis of variance, with post hoc multiple comparisons performed to analyze differences between specific renal segments. Correlation analyses were conducted between cortical RBF values and estimated glomerular filtration rate (eGFR), as well as other renal function parameters.
Results
Despite having a normal eGFR, patients in the NAU stage exhibited significantly reduced RBF (right: 110.84±13.15 mL/100 g/min; left: 94.14±5.24 mL/100 g/min) compared to HVs [right: 133.78±19.19 mL/100 g/min; left: median, 109.00, interquartile range (IQR), 101.53-117.15 mL/100 g/min], with reductions of approximately 17-19% in the bilateral anterior segments (right: adjusted P=0.016; left: adjusted P=0.008). A progressive decline in RBF was observed across advancing disease stages in certain renal segments (e.g., posterior segments) in the NAU group (right: median, 104.57, IQR, 101.90-116.92 mL/100 g/min; left: 95.49±11.60 mL/100 g/min, MAU group (right: 92.07±13.13 mL/100 g/min; left: 82.40±6.76 mL/100 g/min), and DKD group (right: 69.52±17.16 mL/100 g/min; left: 65.75±19.36 mL/100 g/min). The posterior segment emerged as a consistently vulnerable region in the MAU and DKD stages (both adjusted P values
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- The Second School of Clinical Medicine, Hangzhou Normal University, Hangzhou, China.
- Rehabilitation Medicine Center, Department of Radiology, Zhejiang Provincial People's Hospital, Affiliated People's Hospital, Hangzhou Medical College, Hangzhou, China.
- The Second School of Clinical Medicine, Zhejiang Chinese Medical University, Hangzhou, China.
- MR Research, GE Healthcare, Shanghai, China.
- Department of Public Health, Hangzhou Medical College, Hangzhou, China.
- Institute of Artificial Intelligence and Remote Imaging, Hangzhou Medical College, Hangzhou, China.
Zitieren
APA
Fang, W., Song, Q., Cao, F., Zhou, S., Liu, Z., Zhang, Y., Xu, X., & Gong, X. (2026). Three-dimensional pseudo-continuous arterial spin labeling magnetic resonance imaging: an effective imaging technique for early-stage kidney injury in patients with type 2 diabetes. Quantitative Imaging in Medicine and Surgery, 16(4), 299-299. https://doi.org/10.21037/qims-2025-1776
Vancouver
Fang W, Song Q, Cao F, Zhou S, Liu Z, Zhang Y, et al. Three-dimensional pseudo-continuous arterial spin labeling magnetic resonance imaging: an effective imaging technique for early-stage kidney injury in patients with type 2 diabetes. Quantitative Imaging in Medicine and Surgery. 2026;16(4):299-299. doi:10.21037/qims-2025-1776
BibTeX
@article{Fang2026,
author = {Fang, Wenli and Song, Qiaowei and Cao, Fang and Zhou, Sixian and Liu, Zhicheng and Zhang, Yong and Xu, Xiaomin and Gong, Xiangyang},
title = {Three-dimensional pseudo-continuous arterial spin labeling magnetic resonance imaging: an effective imaging technique for early-stage kidney injury in patients with type 2 diabetes},
journal = {Quantitative Imaging in Medicine and Surgery},
year = {2026},
volume = {16},
number = {4},
pages = {299--299},
doi = {10.21037/qims-2025-1776}
}
EUVIMED