EUVIMEDEUVIMED entdecken
Crossref

Evaluation of real-ear to coupler difference (RECD) Values and Test-Retest Reliability in 0.4 cc and 2 cc Coupler Measurements in Young Adults

Murat Şahin, Zeynep Sultan Evin, Zehra Güneş, Leyla Kiraz, Elifnur Tüdün, Samet Kılıç, Mehmet Aslan

Hacettepe University Faculty of Health Sciences Journal · 30.04.2026 · 13 (1) · 143-153

DOI: 10.21020/husbfd.1783593 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Hacettepe University Faculty of Health Sciences Journal, online erschienen am 30.04.2026. Verfasst von Murat Şahin und 6 weiteren Autor:innen. Die Arbeit nennt 15 Literaturangaben. Gefördert von: The Interacoustics Affinity Compact Version 4 Hearing Aid Test and Fitting System used in this study was purchased within the scope of a Scientific Research Pr….

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

The aim of this study was to obtain normative data and examine test-retest reliabilities in HA-2 2cc and 0.4 cc coupler RECD measurements in the young adult Turkish population.Materials and Methods: In this study, 36 participants (17 females, 19 males), aged between 20 and 26 years (mean age = 21.80, SD = 1.27), with normal otoscopic findings, normal bilateral hearing, and no history of outer or middle ear surgery, were evaluated. HA-2 2cc and 0.4 cc RECD measurements, as well as retest measurements, were conducted on both ears of the participants by using insert phones and foam tip.

Results

A statistically significant positive correlation was observed between the HA-2 2 cc and 0.4 cc RECD test–retest measurements. For the 2 cc RECD test–retest results, reliability was found to be moderate at 125 Hz and 10 kHz, excellent at 3 kHz, and good at the other frequencies. For the 0.4 cc RECD test–retest results, reliability was moderate at 1 kHz, 1.5 kHz, 2 kHz, and 10 kHz, and good at the other frequencies. No interaural differences were found in the RECD values obtained with either coupler. A significant difference between male and female participants was observed only at 250 Hz for the 2 cc RECD test results, and at 125 Hz and 250 Hz for the 0.4 cc RECD test results. Across all frequencies, the 2 cc RECD values were higher than the 0.4 cc RECD values.

Conclusion

HA-2 2 cc and 0.4 cc RECD measurements by using insert phones and foam tip are repeatable and clinically reliable methods in young adults.

Förderung

  • The Interacoustics Affinity Compact Version 4 Hearing Aid Test and Fitting System used in this study was purchased within the scope of a Scientific Research Pr…

Zitieren

APA

Şahin, M., Evin, Z. S., Güneş, Z., Kiraz, L., Tüdün, E., Kılıç, S., & Aslan, M. (2026). Evaluation of real-ear to coupler difference (RECD) Values and Test-Retest Reliability in 0.4 cc and 2 cc Coupler Measurements in Young Adults. Hacettepe University Faculty of Health Sciences Journal, 13(1), 143-153. https://doi.org/10.21020/husbfd.1783593

Vancouver

Şahin M, Evin ZS, Güneş Z, Kiraz L, Tüdün E, Kılıç S, et al. Evaluation of real-ear to coupler difference (RECD) Values and Test-Retest Reliability in 0.4 cc and 2 cc Coupler Measurements in Young Adults. Hacettepe University Faculty of Health Sciences Journal. 2026;13(1):143-153. doi:10.21020/husbfd.1783593

BibTeX
@article{ahin2026,
  author = {Şahin, Murat and Evin, Zeynep Sultan and Güneş, Zehra and Kiraz, Leyla and Tüdün, Elifnur and Kılıç, Samet and Aslan, Mehmet},
  title = {Evaluation of real-ear to coupler difference (RECD) Values and Test-Retest Reliability in 0.4 cc and 2 cc Coupler Measurements in Young Adults},
  journal = {Hacettepe University Faculty of Health Sciences Journal},
  year = {2026},
  volume = {13},
  number = {1},
  pages = {143--153},
  doi = {10.21020/husbfd.1783593}
}
Kostenlos starten →