Abstract (Originalsprache)

Objectives

To compare the three-dimensional trueness of three intraoral scanners (IOSs) and two conventional impression workflows, and to determine whether the scanner technologies differed in recording details, and differences in regional reproduction of the preparation. Materials and Method: An in-vitro typodont study evaluated five groups: 3Shape TRIOS, Medit i600, Runyes 3DS, alginate, and addition silicone/polyvinyl siloxane (PVS), with 18 observations per group (total n=90). Mandibular first molar 36 was prepared for a full-coverage crown. A Medit T310 extraoral scan of the reference typodont provided the reference STL. Conventional impressions were made with alginate or two-step puttywash PVS. IOS scanning used no powder or spray and a single operator scanned the models with 3 different IOS scanners. STL files were compared in Geomagic Control X using the built-in initial and best-fit alignment workflow. Best-fit RMS deviation was the primary trueness outcome; signed regional deviations were secondary outcomes.

Results

Median RMS deviation was 37.5 µm for Runyes, 40.3 µm for 3Shape, 75.5 µm for PVS, 80.5 µm for alginate and 86.0 µm for Medit. The overall difference was significant (Kruskal–Wallis H=54.98, p

Zitieren

APA

V, D. C. E., J, D. S. R., Brahmbhatt, D. R., Varma, D. M., Kamaran, D. M., & Mutalya, D. C. (2026). Three-dimensional trueness of three intraoral scanners and two conventional impression techniques in Fixed Dental Prostheses. European Journal of Prosthodontics and Restorative Dentistry. https://doi.org/10.1922/ejprd.v34i13s.2201

Vancouver

V DCE, J DSR, Brahmbhatt DR, Varma DM, Kamaran DM, Mutalya DC. Three-dimensional trueness of three intraoral scanners and two conventional impression techniques in Fixed Dental Prostheses. European Journal of Prosthodontics and Restorative Dentistry. 2026. doi:10.1922/ejprd.v34i13s.2201

BibTeX
@article{V2026,
  author = {V, Dr. Chheda Ekta and J, Dr. Shah Rupal and Brahmbhatt, Dr. Real and Varma, Dr. Monika and Kamaran, Dr. Manimalathi and Mutalya, Dr. Chandrika},
  title = {Three-dimensional trueness of three intraoral scanners and two conventional impression techniques in Fixed Dental Prostheses},
  journal = {European Journal of Prosthodontics and Restorative Dentistry},
  year = {2026},
  doi = {10.1922/ejprd.v34i13s.2201}
}
Kostenlos starten →