Optimal energy management model of a micro-CHP through combined multi-objective PSO–FL–AHP with realistic residential load profile

Farah Ramadhani, Oon Erixno, Marintan Simbolon, Efri Suhartono, Norridah Amin

Clean Energy Science and Technology · 2026-07-06

DOI: 10.18686/cest615 ↗

At a glance

Journal article in Clean Energy Science and Technology, published online on 2026-07-06. Written by Farah Ramadhani and 4 co-authors. 38 references. The full text is freely available (open access, CC BY 4.0).

PovzetekBibliografski podatkiCiteRelated studies

Abstract (original language)

The strength of combined heat and power (CHP) systems in covering the electricity and heat demands has been proven over the last two decades. However, due to their complexity, CHP systems overcome challenges in optimally managing energy sources. This study aims to develop the best energy management model for a residential micro-CHP system that combines photovoltaics, thermal, and fuel cells, employing particle swarm optimization to optimize the model and incorporating fuzzy constraints to reduce power losses. To confirm its superiority, the proposed management model was compared to the conventional following-electrical-load approach. At the same time, the best candidate was selected using the Analytical Hierarchy Process. The results indicate that particle swarm optimization (PSO) significantly enhanced source operations and improved all objective criteria—primary energy saving (PES) (86.4%), net present value (NPV) (101.0%), and CO₂ reduction (5.1%)—compared to the conventional load-following approach; however, it exhibited a loss of power supply probability (LPSP) of approximately 41.7%. Additionally, the fuzzy constraints on the PSO model (PSO–FL (fuzzy logic)) have successfully eliminated the LPSP (0%) while maintaining all criteria at their best values. It has improved the PES, NPV, and CO2 by approximately 9.9%, 47.1%, and 7.1%, respectively. The analytical hierarchy process (AHP) with the best weights of 0.3, 0.4, and 0.3 for the PES, NPV, and CO2 criteria was chosen as the best solution. Prospects for the real implementation of the best model were validated through the operation of a real micro-CHP system.

Cite

APA

Ramadhani, F., Erixno, O., Simbolon, M., Suhartono, E., & Amin, N. (2026). Optimal energy management model of a micro-CHP through combined multi-objective PSO–FL–AHP with realistic residential load profile. Clean Energy Science and Technology. https://doi.org/10.18686/cest615

Vancouver

Ramadhani F, Erixno O, Simbolon M, Suhartono E, Amin N. Optimal energy management model of a micro-CHP through combined multi-objective PSO–FL–AHP with realistic residential load profile. Clean Energy Science and Technology. 2026. doi:10.18686/cest615

BibTeX
@article{Ramadhani2026,
  author = {Ramadhani, Farah and Erixno, Oon and Simbolon, Marintan and Suhartono, Efri and Amin, Norridah},
  title = {Optimal energy management model of a micro-CHP through combined multi-objective PSO–FL–AHP with realistic residential load profile},
  journal = {Clean Energy Science and Technology},
  year = {2026},
  doi = {10.18686/cest615}
}