EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

CT-navigated C2 Pedicle Screw insertion using dynamic reference array on C2 spinous process: A Novel Technique

Vinay Hiralal Patel, Dheeraj Batheja, Aashish Ghodke, Sujay Dheerendra, Shashank Chitgopkar, Jayesh Trivedi, Sudarshan Munigangaiah

Medical Research Archives · 26.03.2024 · 12 (3)

DOI: 10.18103/mra.v12i3.5062 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medical Research Archives, online erschienen am 26.03.2024. Verfasst von Vinay Hiralal Patel und 6 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Spine surgeons have endeavoured to improve the accuracy of pedicle screw insertion. Computed tomography (CT) guided navigation has been helpful in precisely passing pedicle screws even further accurately but, there were shortcomings noted with the technique due to movement between reference frame and anatomical landmarks, especially in the cervical spine which led to injury of vital neurovascular structures. Thus, there was a need for developing a technique which would eliminate the inherent error due to movement in the vertebral body while passing screws. Research Question: Can using C2 spinous process as an attachment for the reference array improve accuracy of C2 pedicle screws. Material and Methods: We prospectively studied data of 10 patients (20 screws) in whom Computed tomography navigated C2 pedicle screws insertion was carried out using the reference array on C2 spinous process. Accuracy of pedicle screws were confirmed by post instrumentation Computed tomography scan immediately intra operatively.

Results

With the presented technique overall breach rate was 5% with one screw having a medial breach of grade 1 with no incidence of neurovascular injury or need for further revision. Discussion and Conclusion: Results from this study shows better accuracy than other techniques described to pass C2 pedicle screws eliminating the error in movement from the cervical vertebrae and the reference frame being nearest to the C2 pedicle. Although there is a learning curve with the adoption of the navigation system, with experience, the challenges associated with Cervical pedicle screws (CPS) insertion can be overcome.

Zitieren

APA

Patel, V. H., Batheja, D., Ghodke, A., Dheerendra, S., Chitgopkar, S., Trivedi, J., & Munigangaiah, S. (2024). CT-navigated C2 Pedicle Screw insertion using dynamic reference array on C2 spinous process: A Novel Technique. Medical Research Archives, 12(3). https://doi.org/10.18103/mra.v12i3.5062

Vancouver

Patel VH, Batheja D, Ghodke A, Dheerendra S, Chitgopkar S, Trivedi J, et al. CT-navigated C2 Pedicle Screw insertion using dynamic reference array on C2 spinous process: A Novel Technique. Medical Research Archives. 2024;12(3). doi:10.18103/mra.v12i3.5062

BibTeX
@article{Patel2024,
  author = {Patel, Vinay Hiralal and Batheja, Dheeraj and Ghodke, Aashish and Dheerendra, Sujay and Chitgopkar, Shashank and Trivedi, Jayesh and Munigangaiah, Sudarshan},
  title = {CT-navigated C2 Pedicle Screw insertion using dynamic reference array on C2 spinous process: A Novel Technique},
  journal = {Medical Research Archives},
  year = {2024},
  volume = {12},
  number = {3},
  doi = {10.18103/mra.v12i3.5062}
}
Kostenlos starten →