EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Valve-in-Valve Transcatheter Aortic Valve Replacement for Failed Surgical Bioprostheses: Insights from a Single-Center Experience with the Mitroflow Valve

Anne Therese C. Lim, MD, Kaylee Weigel, MS, Derek Anderson, Jason Go, MD, Ismail Bekdash, Awais Aslam, MD, Cornelius M. Dyke, MD und 1 weitere

Medical Research Archives · 30.09.2026 · 14 (9)

DOI: 10.18103/mra.2026.0576 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medical Research Archives, online erschienen am 30.09.2026. Verfasst von Anne Therese C. Lim und 12 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR) has become a mainstream, less invasive alternative to redo surgery for failed surgical aortic bioprostheses, but certain surgical valve designs remain a source of concern. The Mitroflow bioprosthesis, with externally mounted leaflets, degenerates earlier than other surgical valves and has historically carried heightened risk of coronary obstruction and residual stenosis during ViV TAVR. We review contemporary ViV TAVR outcomes in the context of our single-center experience of 105 consecutive procedures (2012 to 2025) comparing failed Mitroflow (n=37) with other surgical bioprostheses (n=68). Mitroflow valves failed significantly earlier compared to other surgical valves (8.46 vs 11.16 years, p

Zitieren

APA

Lim, A. T. C., MD, Weigel, K., MS, Anderson, D., Go, J., MD, Bekdash, I., Aslam, A., MD, Dyke, C. M., MD, & Haldis, T. (2026). Valve-in-Valve Transcatheter Aortic Valve Replacement for Failed Surgical Bioprostheses: Insights from a Single-Center Experience with the Mitroflow Valve. Medical Research Archives, 14(9). https://doi.org/10.18103/mra.2026.0576

Vancouver

Lim ATC, MD, Weigel K, MS, Anderson D, Go J, et al. Valve-in-Valve Transcatheter Aortic Valve Replacement for Failed Surgical Bioprostheses: Insights from a Single-Center Experience with the Mitroflow Valve. Medical Research Archives. 2026;14(9). doi:10.18103/mra.2026.0576

BibTeX
@article{Lim2026,
  author = {Lim, Anne Therese C. and MD and Weigel, Kaylee and MS and Anderson, Derek and Go, Jason and MD and Bekdash, Ismail and Aslam, Awais and MD and Dyke, Cornelius M. and MD and Haldis, Thomas},
  title = {Valve-in-Valve Transcatheter Aortic Valve Replacement for Failed Surgical Bioprostheses: Insights from a Single-Center Experience with the Mitroflow Valve},
  journal = {Medical Research Archives},
  year = {2026},
  volume = {14},
  number = {9},
  doi = {10.18103/mra.2026.0576}
}
Kostenlos starten →