Recovery of atrioventricular conduction after transcatheter aortic valve replacement: A single center experience
Indian Pacing and Electrophysiology Journal · 2026-09 · 26 (5) · 509-515
DOI: 10.1016/j.ipej.2026.05.001 ↗Kurz gefasst
Fachartikel in der Zeitschrift Indian Pacing and Electrophysiology Journal, 2026-09. Verfasst von Dóra Krányák und 7 weiteren Autor:innen. Beteiligte Einrichtung: University of Szeged, Department of Internal Medicine, Cardiology Center, Division of Electrophysiology, Szeged, Hungary. Electronic address: kranyak…. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
INTRODUCTION: Limited data are available on long-term changes in the conduction system following transcatheter aortic valve implantation (TAVI). OBJECTIVE: To assess atrioventricular (AV) conduction changes after TAVI and examine the relationship between pacemaker (PM)-derived parameters and surface ECG findings. METHODS: We retrospectively analyzed patients who underwent PM implantation after TAVI between July 2014 and June 2023. Demographic, imaging, procedural, and ECG data were collected. A dedicated follow-up (FU) visit, including device interrogation and a 12-lead ECG recorded during temporary VVI pacing at 30 bpm, was performed on average 1.7 ± 1.3 years post-implant. Based on FU ECGs, patients were classified as having persistent (persAVB) or regressive AV block (regrAVB). RESULTS: Among 377 TAVI procedures, 33 PM implantations (8.7%) were performed at a mean of 5.7 days after the procedure. Indications included third-degree AV block in 27 (81%), second-degree AV block in 3 (9%), and significant bradycardia in 3 (9%). FU ECGs were available for 14 patients; 7 (50%) showed conduction recovery. Baseline QRS duration was significantly wider in persAVB than in regrAVB (107.1 ± 27.3 ms vs. 80.7 ± 1.6 ms; p = 0.038). Median right ventricular pacing (RVp) burden was substantially higher in persAVB (100% [IQR 98.8-100%]) compared with regrAVB (0% [IQR 0-2.5%]; p < 0.001). Pacemaker dependency was present in 28% of persAVB patients and in none of the regrAVB group. CONCLUSIONS: A substantial proportion of patients showed recovery of AV- conduction over time, particularly those without pre-existing conduction disturbances. The degree of RVp closely reflected conduction recovery status during follow-up.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- University of Szeged, Department of Internal Medicine, Cardiology Center, Division of Electrophysiology, Szeged, Hungary. Electronic address: kranyak.dora@med.u-szeged.hu.
- University of Szeged, Department of Internal Medicine, Cardiology Center, Division of Electrophysiology, Szeged, Hungary.
Zitieren
APA
Krányák, D., Gausz, F. D., Saleem, G., Ruzsa, Z., Szűcsborús, T., Vámos, M., Szili-Török, T., & Sághy, L. (2026). Recovery of atrioventricular conduction after transcatheter aortic valve replacement: A single center experience. Indian Pacing and Electrophysiology Journal, 26(5), 509-515. https://doi.org/10.1016/j.ipej.2026.05.001
Vancouver
Krányák D, Gausz FD, Saleem G, Ruzsa Z, Szűcsborús T, Vámos M, et al. Recovery of atrioventricular conduction after transcatheter aortic valve replacement: A single center experience. Indian Pacing and Electrophysiology Journal. 2026;26(5):509-515. doi:10.1016/j.ipej.2026.05.001
BibTeX
@article{Krnyk2026,
author = {Krányák, Dóra and Gausz, Flóra Diána and Saleem, George and Ruzsa, Zoltán and Szűcsborús, Tamás and Vámos, Máté and Szili-Török, Tamás and Sághy, László},
title = {Recovery of atrioventricular conduction after transcatheter aortic valve replacement: A single center experience},
journal = {Indian Pacing and Electrophysiology Journal},
year = {2026},
volume = {26},
number = {5},
pages = {509--515},
doi = {10.1016/j.ipej.2026.05.001}
}
EUVIMED