EUVIMEDEUVIMED entdecken
Crossref

DEVELOPMENT OF AN ELECTROCHEMICAL SENSOR FOR MORE RAPID HIF-1Α DETECTION AS AN ALTERNATIVE TO WESTERN BLOT ANALYSIS

Kübra Kaya, Ahmet Uçar, Araz Norouz Dizaji, Fatma Doğan Guzel, Didem Kozaci

Eskişehir Technical University Journal of Science and Technology A - Applied Sciences and Engineering · 27.03.2026 · 27 (1) · 63-78

DOI: 10.18038/estubtda.1737583 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Eskişehir Technical University Journal of Science and Technology A - Applied Sciences and Engineering, online erschienen am 27.03.2026. Verfasst von Kübra Kaya und 4 weiteren Autor:innen. Die Arbeit nennt 62 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Oxygen levels in the body/and organs significantly influence the regulation of metabolic reactions. Hypoxia, a decrease in oxygen levels, can potentially trigger various signals leading to serious health issues. This study aimed to develop an electrochemical immunosensor platform for rapidly and accurately detecting the hypoxia biomarker, HIF-1α protein. In this regard, screen-printed gold electrodes were modified using 11-mercaptoundecanoic acid and 3-mercapto-1-propanol (as a spacer) to generate functional carboxyl groups. Employing EDC-NHS chemistry facilitated the immobilization of HIF-1α antibodies, which were then utilized for the selective and specific recognition of their target. Electrochemical voltametric measurements were conducted using a potassium ferri/ferrocyanide redox couple in both hypoxia-cultured cell lysates and phosphate-buffered saline spiked with HIF-1α protein.In addition to electrochemical measurements, Western blotting (WB) was performed to compare findings with electrochemical results and to confirm the presence of HIF-1α in hypoxic cell lysates. While WB results only exhibited the qualitative presence of the respective antigen in lysates, significant signal decreases were observed in both Cyclic Voltammetry (CV) and Differential Pulse Voltammetry (DPV) measurements due to specific antibody-target binding, emphasizing the electrochemical sensor’s performance for more rapid and quantitative protein detection. The low limit of detection (1.46 nM) suggests the potential of our proposed immunosensor platform for detecting HIF-1α protein within a clinically significant range, which is highly desired for point-of-care applications. This study is one of its kind in the literature to develop an electrochemical immunosensor platform for the rapid detection of HIF-1α. The sensor's ability to provide inexpensive, rapid, and quantitative measurements is a significant advancement for HIF-1 α detection.

Zitieren

APA

Kaya, K., Uçar, A., Dizaji, A. N., Guzel, F. D., & Kozaci, D. (2026). DEVELOPMENT OF AN ELECTROCHEMICAL SENSOR FOR MORE RAPID HIF-1Α DETECTION AS AN ALTERNATIVE TO WESTERN BLOT ANALYSIS. Eskişehir Technical University Journal of Science and Technology A - Applied Sciences and Engineering, 27(1), 63-78. https://doi.org/10.18038/estubtda.1737583

Vancouver

Kaya K, Uçar A, Dizaji AN, Guzel FD, Kozaci D. DEVELOPMENT OF AN ELECTROCHEMICAL SENSOR FOR MORE RAPID HIF-1Α DETECTION AS AN ALTERNATIVE TO WESTERN BLOT ANALYSIS. Eskişehir Technical University Journal of Science and Technology A - Applied Sciences and Engineering. 2026;27(1):63-78. doi:10.18038/estubtda.1737583

BibTeX
@article{Kaya2026,
  author = {Kaya, Kübra and Uçar, Ahmet and Dizaji, Araz Norouz and Guzel, Fatma Doğan and Kozaci, Didem},
  title = {DEVELOPMENT OF AN ELECTROCHEMICAL SENSOR FOR MORE RAPID HIF-1Α DETECTION AS AN ALTERNATIVE TO WESTERN BLOT ANALYSIS},
  journal = {Eskişehir Technical University Journal of Science and Technology A - Applied Sciences and Engineering},
  year = {2026},
  volume = {27},
  number = {1},
  pages = {63--78},
  doi = {10.18038/estubtda.1737583}
}
Kostenlos starten →