EUVIMEDEUVIMED entdecken
Open Access

Development of an Electrochemical, Aptamer-Based Sensor for Dynamic Detection of Neuropeptide Y

Jordan M Seibold, Sanduni W Abeykoon, Ashley E Ross iD, Ryan J White iD

ACS Sensors · 22.12.2023 · 8 (12) · 4504-4511

DOI: 10.1021/acssensors.3c00855 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Sensors, online erschienen am 30.11.2023. Verfasst von Jordan M Seibold und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, University of Cincinnati, 312 College Dr. 404 Crosley Tower, Cincinnati, Ohio 45221-0172, United States. Hauptthemen laut MEDLINE: Aptamers, Nucleotide, Biosensing Techniques. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 54 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIAID NIH HHS, National Institute of Allergy and Infectious Diseases, Alfred P. Sloan Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The ability to monitor dynamic changes in neuropeptide Y (NPY) levels in complex environments can have an impact on many fields, including neuroscience and immunology. Here, we describe the development of an electrochemical, aptamer-based (E-AB) sensor for the dynamic (reversible) measurement of physiologically relevant (nanomolar) concentrations of neuropeptide Y. The E-AB sensors are fabricated using a previously described 80 nucleotide aptamer1 reported to specifically bind NPY with a binding affinity Kd = 0.3 ± 0.2 uM. We investigated two redox tag placement locations on the aptamer sequence (terminal vs internal) and various sensor fabrication and interrogation parameters to tune the performance of the resulting sensor. The best-performing sensor architecture displayed a physiologically relevant dynamic range (nM) and low limit of detection and is selective among competitors and similar molecules. The development of this sensor accomplishes two breakthroughs: first, the development of a nonmicrofluidic aptamer-based electrochemical sensor that can detect NPY on a physiologically relevant (seconds to minutes) time scale and across a relevant concentration range; second, the expansion of the range of molecules for which an electrochemical, aptamer-based sensor can be used.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Aptamers, NucleotideBiosensing TechniquesNeuropeptide YOxidation-Reduction

Stichwörter der Autor:innen

aptamerbiosensorsdynamic measurementselectrochemistryinflammationneuropeptides

Substanzen

Neuropeptide YAptamers, Nucleotide

Autor:innen und Institutionen

  • Department of Chemistry, University of Cincinnati, 312 College Dr. 404 Crosley Tower, Cincinnati, Ohio 45221-0172, United States.
  • Department of Electrical and Computer Engineering,University of Cincinnati,2901 Woodside Drive,Cincinnati,Ohio 45221, United States.

ORCID-Profile: Ashley E Ross, Ryan J White

Förderung

  • NIAID NIH HHS
  • National Institute of Allergy and Infectious Diseases
  • Alfred P. Sloan Foundation

Zitieren

APA

Seibold, J. M., Abeykoon, S. W., Ross, A. E., & White, R. J. (2023). Development of an Electrochemical, Aptamer-Based Sensor for Dynamic Detection of Neuropeptide Y. ACS Sensors, 8(12), 4504-4511. https://doi.org/10.1021/acssensors.3c00855

Vancouver

Seibold JM, Abeykoon SW, Ross AE, White RJ. Development of an Electrochemical, Aptamer-Based Sensor for Dynamic Detection of Neuropeptide Y. ACS Sensors. 2023;8(12):4504-4511. doi:10.1021/acssensors.3c00855

BibTeX
@article{Seibold2023,
  author = {Seibold, Jordan M and Abeykoon, Sanduni W and Ross, Ashley E and White, Ryan J},
  title = {Development of an Electrochemical, Aptamer-Based Sensor for Dynamic Detection of Neuropeptide Y},
  journal = {ACS Sensors},
  year = {2023},
  volume = {8},
  number = {12},
  pages = {4504--4511},
  doi = {10.1021/acssensors.3c00855}
}
Kostenlos starten →