EUVIMEDEUVIMED entdecken
Open Access

Fluoroscopy-free Atrial Transseptal Puncture

Mark D McCauley, Nisarg Patel, Scott J Greenberg, Joanna E Molina-Razavi, Payam Safavi-Naeini, Mehdi Razavi

European Journal of Arrhythmia & Electrophysiology · 2016

DOI: 10.17925/ejae.2016.02.02.57 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of Arrhythmia & Electrophysiology, 2016. Verfasst von Mark D McCauley und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medicine, Section of Cardiology, The University of Illinois at Chicago and the Jesse Brown VA Medical Center, Chicago, Illinois, US. Die Arbeit wurde bisher 13-mal zitiert (Crossref). Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NHLBI NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Fluoroscopy is traditionally used in atrial transseptal puncture (TSP); however fluoroscopy exposes patient and physician to excess radiation. Here, we describe a feasibility study of a zero-fluoroscopy transseptal puncture (ZFTSP) technique utilising electroanatomical mapping (EAM) and intracardiac echo (ICE) in a small case series of patients undergoing ablation for atrial fibrillation (AF). We then compare this technique to other established ZFTSP techniques for paroxysmal AF ablation.

Methods

Seven patients received ZFTSP. An Acunav ™ ICE catheter (Biosense Webster Inc., California, US) was placed in the right atrium, then an Agilis ™ sheath (St. Jude Medical, Saint Paul, Minnesota, US) was established into the inferior vena cava. A ThermoCool ® SmartTouch ™ catheter (Biosense Webster Inc., California, US) was inserted through the Agilis to map the fossa ovalis. Mapping catheter exchange for dilator and needle allowed for facile ZFTSP. AF outcome, fluoroscopy times, and procedure times were compared with eight age-matched control patients.

Results

There were no significant differences in age, body mass index (BMI) or AF duration between the two groups and no immediate complications. ZFTSP procedure time was 183.9±33.7 minutes versus 293.13±129.9 minutes for TSP-only controls (p=0.05). Fluoroscopy time was 17.5±14.1 minutes in ZFTSP patients versus 73.4±50.3 minutes in controls (p=0.01). AF recurrence in ZFTSP patients was 14% versus 25% in controls.

Conclusion

ZFTSP utilising ICE and EAM is safe, effective, and time-efficient. There is a small but significant reduction in radiation exposure to patient and physician by the use of this technique.

Schlagwörter

Stichwörter der Autor:innen

Atrial fibrillationelectro-anatomical mappingintracardiac echocardiographytransseptal puncturezero-fluoroscopy

Autor:innen und Institutionen

  • Department of Medicine, Section of Cardiology, The University of Illinois at Chicago and the Jesse Brown VA Medical Center, Chicago, Illinois, US.
  • The Wright Center, Wilkes-Barre, Pennsylvania, US.
  • The Texas Heart Institute and Baylor College of Medicine, Houston, Texas, US.

Förderung

  • NHLBI NIH HHS

Zitieren

APA

McCauley, M. D., Patel, N., Greenberg, S. J., Molina-Razavi, J. E., Safavi-Naeini, P., & Razavi, M. (2016). Fluoroscopy-free Atrial Transseptal Puncture. European Journal of Arrhythmia & Electrophysiology. https://doi.org/10.17925/ejae.2016.02.02.57

Vancouver

McCauley MD, Patel N, Greenberg SJ, Molina-Razavi JE, Safavi-Naeini P, Razavi M. Fluoroscopy-free Atrial Transseptal Puncture. European Journal of Arrhythmia & Electrophysiology. 2016. doi:10.17925/ejae.2016.02.02.57

BibTeX
@article{McCauley2016,
  author = {McCauley, Mark D and Patel, Nisarg and Greenberg, Scott J and Molina-Razavi, Joanna E and Safavi-Naeini, Payam and Razavi, Mehdi},
  title = {Fluoroscopy-free Atrial Transseptal Puncture},
  journal = {European Journal of Arrhythmia & Electrophysiology},
  year = {2016},
  doi = {10.17925/ejae.2016.02.02.57}
}
Kostenlos starten →