EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Clinical application of the transseptal puncture technique using a biplane positioning method with left atrial 3D-CT

Yi-Chen Yang, Jun Hou, Yi Li, Tan Chen, Ya-Feng Zhou, Rui-Qing Dong

Frontiers in Cardiovascular Medicine · 14.04.2026 · 13

DOI: 10.3389/fcvm.2026.1610164 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Cardiovascular Medicine, online erschienen am 14.04.2026. Verfasst von Yi-Chen Yang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, The Fourth Affiliated Hospital of Soochow University, Suzhou, China. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Traditional transseptal puncture (TSP) relies on x-ray imaging and anatomical landmarks, which poses challenges in patients with atrial structural variations or overweight. Furthermore, emerging interventional techniques demand precise puncture site localization. This feasibility study evaluates the safety and efficacy of a novel biplane positioning method guided by left atrial (LA) 3D-CT reconstruction for TSP.

Methods

A retrospective analysis included 100 atrial fibrillation patients undergoing radiofrequency catheter ablation (RFCA) between July 2023 and March 2024. Preoperative LA-enhanced CT scans were performed to reconstruct 3D models. Key measurements included vertebral height (H), horizontal distance (X) from the target puncture point (O) to the anterior spine edge at 45° right anterior oblique (RAO) view, and vertical distance (Y) between O and the great cardiac vein. Intraoperative biplane localization integrated CT-derived ratios (X/H, Y/H) with fluoroscopy. Statistical analyses compared outcomes across LA size subgroups.

Results

All patients achieved successful TSP without complications (e.g., cardiac tamponade, thromboembolism). The mean X/H and Y/H ratios were 0.8 ± 0.2 and 0.5 ± 0.1, respectively. Patients with larger LA diameters (≥50 mm) exhibited significantly greater X values (16.8 ± 3.3 mm vs. 13.6 ± 4.2 mm, P = 0.034). In 17 patients with unclear LA posterior borders on fluoroscopy (mean BMI 27.2 ± 3.5 vs. 24.9 ± 3.2 in others, P = 0.009), the method ensured safe puncture. The mean distance from the puncture site to the right inferior pulmonary vein was 24.2 ± 5.5 mm.

Discussion

The LA 3D-CT-guided biplane positioning method demonstrates feasibility, accuracy, and safety for TSP in atrial fibrillation patients, including those with enlarged atria, structural anomalies, or overweight. The protocol is feasible within a limited, single-center cohort.

Schlagwörter

Stichwörter der Autor:innen

atrial 3D-CTatrial fibrillationbiplane positioningcardiac interventiontransseptal puncture

Autor:innen und Institutionen

  • Department of Cardiology, The Fourth Affiliated Hospital of Soochow University, Suzhou, China.

Zitieren

APA

Yang, Y. C., Hou, J., Li, Y., Chen, T., Zhou, Y. F., & Dong, R. Q. (2026). Clinical application of the transseptal puncture technique using a biplane positioning method with left atrial 3D-CT. Frontiers in Cardiovascular Medicine, 13. https://doi.org/10.3389/fcvm.2026.1610164

Vancouver

Yang YC, Hou J, Li Y, Chen T, Zhou YF, Dong RQ. Clinical application of the transseptal puncture technique using a biplane positioning method with left atrial 3D-CT. Frontiers in Cardiovascular Medicine. 2026;13. doi:10.3389/fcvm.2026.1610164

BibTeX
@article{Yang2026,
  author = {Yang, Yi-Chen and Hou, Jun and Li, Yi and Chen, Tan and Zhou, Ya-Feng and Dong, Rui-Qing},
  title = {Clinical application of the transseptal puncture technique using a biplane positioning method with left atrial 3D-CT},
  journal = {Frontiers in Cardiovascular Medicine},
  year = {2026},
  volume = {13},
  doi = {10.3389/fcvm.2026.1610164}
}
Kostenlos starten →