EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Echocardiographic Biatrial Remodelling and Diastolic Function Assessment in Long-Term Follow-Up after Typical Atrial Flutter Ablation

Pilar Cabanas-Grandío, Javier García-Seara, Francisco Gude, José Luis Martínez-Sande, Xesus Alberte Fernández-López, Felipe Bisbal, Emad Abu-Assi, José Ramón González-Juanatey

Journal of Cardiovascular Medicine and Cardiology · 2014

DOI: 10.17352/2455-2976.000003 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Cardiovascular Medicine and Cardiology, 2014. Verfasst von Pilar Cabanas-Grandío und 7 weiteren Autor:innen. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

A reverse left atrial (LA) remodelling after atrial fibrillation (AF) ablation has been reported and a relationship between diastolic function and AF is well known. However, there is little information about atrial remodelling and diastolic function after cavotricuspid isthmus (CTI) ablation. We aimed to evaluate long-term biatrial remodelling and diastolic function in patients undergoing CTI ablation.

Methods

A transthoracic echocardiography was performed at baseline and at long-term follow-up (6.3 ± 0.5 years) in a total of 39 patients who underwent AFl ablation. Right atrial end diastolic areas (RAEDA) and end systolic areas (RAESA), right atrial contraction fraction (RACF), mitral A wave velocity, E/A rate and LA diameter were measured. They were compared using the Wilcoxon rank sum test.

Results

Mean (SD) age was 64 (10) years, 82% male, 49% hypertension and 44% prior AF episodes. Basal RAEDA and RAESA were higher than at follow-up: median (IQR) of 24.6 cm2 (19.8-28.2) vs. 20.0 cm2 (16.0-25.0), p = 0.017 and 17.4 cm2 (13.0-19.3) vs. 12.0 cm2 (9.8-17.0), p = 0.001, respectively. RACF was higher at follow-up: 0.41 (0.35-0.45) vs. 0.31 (0.19-0.37), p = 0.001. Basal mitral A wave velocity was lower than at follow-up: 0.51 (0.4-0.6) vs. 0.78 (0.7-0.9), p =0.001 and E/A rate was higher 1.9 (1.2-3.1) vs. 0.9 (0.7-1.1), p = 0.001. LA diameter at baseline was 44.8 mm (39.3-50.7) vs. 46 mm (41.5-51.5) at follow-up, p

Zitieren

APA

Cabanas-Grandío, P., García-Seara, J., Gude, F., Martínez-Sande, J. L., Fernández-López, X. A., Bisbal, F., Abu-Assi, E., & González-Juanatey, J. R. (2014). Echocardiographic Biatrial Remodelling and Diastolic Function Assessment in Long-Term Follow-Up after Typical Atrial Flutter Ablation. Journal of Cardiovascular Medicine and Cardiology. https://doi.org/10.17352/2455-2976.000003

Vancouver

Cabanas-Grandío P, García-Seara J, Gude F, Martínez-Sande JL, Fernández-López XA, Bisbal F, et al. Echocardiographic Biatrial Remodelling and Diastolic Function Assessment in Long-Term Follow-Up after Typical Atrial Flutter Ablation. Journal of Cardiovascular Medicine and Cardiology. 2014. doi:10.17352/2455-2976.000003

BibTeX
@article{CabanasGrando2014,
  author = {Cabanas-Grandío, Pilar and García-Seara, Javier and Gude, Francisco and Martínez-Sande, José Luis and Fernández-López, Xesus Alberte and Bisbal, Felipe and Abu-Assi, Emad and González-Juanatey, José Ramón},
  title = {Echocardiographic Biatrial Remodelling and Diastolic Function Assessment in Long-Term Follow-Up after Typical Atrial Flutter Ablation},
  journal = {Journal of Cardiovascular Medicine and Cardiology},
  year = {2014},
  doi = {10.17352/2455-2976.000003}
}
Kostenlos starten →