EUVIMEDEUVIMED entdecken
Crossref

Non-fluoroscopic ablation of typical atrial flutter: effectiveness and safety

M. A. Podianov, O. V. Sapelnikov, D. I. Cherkashin, D. F. Ardus, T. M. Uskach, A. A. Kulikov, A. V. Vereshchagina, I. R. Grishin, K. B. Timizheva, G. K. Ramazanov, M. F. Demurchev, A. S. Omelianenko und 2 weitere

Journal of Arrhythmology · 13.01.2026 · 32 (4) · 37-44

DOI: 10.35336/va-1558 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Arrhythmology, online erschienen am 13.01.2026. Verfasst von M. A. Podianov und 13 weiteren Autor:innen. Die Arbeit nennt 32 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aim

To evaluate the effectiveness and safety of catheter treatment of typical atrial flutter (AFl) using exclusively intracardiac echocardiography (ICE) compared to the fluoroscopic method. Material and methods . There were 176 patients with typical AFl (88 patients in each group). The study group consisted of patients who underwent radiofrequency ablation (RFA) with intracardiac ultrasound visualization only (ZF - Zero Fluoro). The comparison group included patients who underwent RFA of the AFl using minimal fluoroscopy time and ICE (MF - Minimal Fluoro). The follow-up period was 12 months.

Results

Intraoperative success rate was 100% in both groups. The absence of recurrence of AFl during the follow-up period was comparable (94.3% vs. 96.6%, p=0.4703). No acute or delayed complications were reported. Fluoroscopy was used in none patient who underwent the procedure under intracardiac ultrasound guidance (p < 0.001). Surgery time and overall RF-ablation time did not differ statistically (69.4 min vs. 63.9 min, p=0.1030; 9.1 min vs. 8.3 min, p=0.1606, respectively) in the MF- and ZF-group.

Conclusion

Catheter RFA of a typical AFl with ICE-visualization is feasible without the use of fluoroscopy, with comparable efficiency and safety results.

Zitieren

APA

Podianov, M. A., Sapelnikov, O. V., Cherkashin, D. I., Ardus, D. F., Uskach, T. M., Kulikov, A. A., Vereshchagina, A. V., Grishin, I. R., Timizheva, K. B., Ramazanov, G. K., Demurchev, M. F., Omelianenko, A. S., Lukin, I. B., & Shiryaev, A. A. (2026). Non-fluoroscopic ablation of typical atrial flutter: effectiveness and safety. Journal of Arrhythmology, 32(4), 37-44. https://doi.org/10.35336/va-1558

Vancouver

Podianov MA, Sapelnikov OV, Cherkashin DI, Ardus DF, Uskach TM, Kulikov AA, et al. Non-fluoroscopic ablation of typical atrial flutter: effectiveness and safety. Journal of Arrhythmology. 2026;32(4):37-44. doi:10.35336/va-1558

BibTeX
@article{Podianov2026,
  author = {Podianov, M. A. and Sapelnikov, O. V. and Cherkashin, D. I. and Ardus, D. F. and Uskach, T. M. and Kulikov, A. A. and Vereshchagina, A. V. and Grishin, I. R. and Timizheva, K. B. and Ramazanov, G. K. and Demurchev, M. F. and Omelianenko, A. S. and Lukin, I. B. and Shiryaev, A. A.},
  title = {Non-fluoroscopic ablation of typical atrial flutter: effectiveness and safety},
  journal = {Journal of Arrhythmology},
  year = {2026},
  volume = {32},
  number = {4},
  pages = {37--44},
  doi = {10.35336/va-1558}
}
Kostenlos starten →