EUVIMEDEUVIMED entdecken
Crossref

A study of the mechanical behavior of knitted nitinol wire sleeves under radial compression and their test application as stents for esophageal and large-vessel stent grafts

Marina A. Kovaleva, Tat’yana V. Chaykovskaya, Ekaterina S. Marchenko

Vestnik Tomskogo gosudarstvennogo universiteta. Matematika i mekhanika · 2026

DOI: 10.17223/19988621/102/10 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Vestnik Tomskogo gosudarstvennogo universiteta. Matematika i mekhanika, 2026. Verfasst von Marina A. Kovaleva und 2 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study investigates the mechanical behavior of knitted nickel-titanium (TiNi) wire sleeves under radial compression to evaluate their potential as elements for esophageal and large-vessel stent grafts. Sleeves made from wires with diameters of 60, 150, and 180 μm were subjected to cyclic radial compression and unloading tests. The results demonstrate a significant influence of wire diameter on radial force, with thicker wires (150 and 180 μm) generating higher forces. The tests revealed the samples' ability to withstand over 70% deformation without failure and exhibited almost complete shape recovery upon unloading, indicating their suitability for catheter-based delivery. Comparison with commercial esophageal stents showed that the sleeves fabricated from 150 and 180 μm wire produced radial forces comparable to those of clinical standards (e.g., 146 N versus 150 N at 50% compression), making them promising candidates for esophageal applications. In contrast, the sleeve made from 60 μm wire generated substantially lower forces. However, its force values at an oversize ratio of 1.4 were comparable to those of stent grafts for large arteries (4.5 N versus 4.2 N for the E-vita Open Plus device), suggesting its potential use in aortic stent grafts deliverable through catheters with a diameter of 4 mm or greater. The study concludes that personalized stent selection requires further computer modeling of patient-specific vessels or esophagus mechanics.

Zitieren

APA

Kovaleva, M. A., Chaykovskaya, T. V., & Marchenko, E. S. (2026). A study of the mechanical behavior of knitted nitinol wire sleeves under radial compression and their test application as stents for esophageal and large-vessel stent grafts. Vestnik Tomskogo gosudarstvennogo universiteta. Matematika i mekhanika. https://doi.org/10.17223/19988621/102/10

Vancouver

Kovaleva MA, Chaykovskaya TV, Marchenko ES. A study of the mechanical behavior of knitted nitinol wire sleeves under radial compression and their test application as stents for esophageal and large-vessel stent grafts. Vestnik Tomskogo gosudarstvennogo universiteta. Matematika i mekhanika. 2026. doi:10.17223/19988621/102/10

BibTeX
@article{Kovaleva2026,
  author = {Kovaleva, Marina A. and Chaykovskaya, Tat’yana V. and Marchenko, Ekaterina S.},
  title = {A study of the mechanical behavior of knitted nitinol wire sleeves under radial compression and their test application as stents for esophageal and large-vessel stent grafts},
  journal = {Vestnik Tomskogo gosudarstvennogo universiteta. Matematika i mekhanika},
  year = {2026},
  doi = {10.17223/19988621/102/10}
}
Kostenlos starten →