EUVIMEDEUVIMED entdecken
Crossref

Effect of orifice diameter, depth of air injection, and air flow rate on oxygen transfer in a pilot-scale, full lift, hypolimnetic aerator

K.I. Ashley, D.S. Mavinic, K.J. Hall

Journal of Environmental Engineering and Science · 01.11.2013 · 8 (1) · 11-22

DOI: 10.1680/jees.2013.0002 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Environmental Engineering and Science, erschienen am 01.11.2013. Verfasst von K.I. Ashley und 2 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 30 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A pilot-scale, full lift, hypolimnetic aerator was used to examine the effect of diffuser pore diameter, depth of diffuser submergence, and gas flow rate on oxygen transfer, using four standard units of measure for quantifying oxygen transfer: (a) KLa20 (h−1), the oxygen transfer coefficient at 20 °C; (b) SOTR (g O2·h−1), the standard oxygen transfer rate; (c) SAE (g O2·kWh−1), the standard aeration efficiency and (d) SOTE (%), the standard oxygen transfer efficiency. Diffuser depth (1·5 and 2·9 m) exerted a significant effect on KLa20, SOTR, SAE, and SOTE, with all units of measure increasing in response to increased diffuser depth. Both KLa20 and SOTR responded positively to increased gas flow rates (10, 20, 30, and 40 L·min−1), whereas both SAE and SOTE responded negatively. Orifice diameter (140, 400, and 800 µm) exerted a significant effect on KLa20, SOTR, SAE, and SOTE, with all units of measure increasing with decreasing orifice size. These experiments demonstrate how competing design factors interact to determine overall oxygen transfer rates in full lift hypolimnetic aeration systems. The practical application for full lift hypolimnetic aerator design is to maximize the surface area of the bubbles, use fine (i.e., ∼140 μm) pore diameter diffusers, and locate the diffusers at the maximum practical depth.

Zitieren

APA

Ashley, K., Mavinic, D., & Hall, K. (2013). Effect of orifice diameter, depth of air injection, and air flow rate on oxygen transfer in a pilot-scale, full lift, hypolimnetic aerator. Journal of Environmental Engineering and Science, 8(1), 11-22. https://doi.org/10.1680/jees.2013.0002

Vancouver

Ashley K, Mavinic D, Hall K. Effect of orifice diameter, depth of air injection, and air flow rate on oxygen transfer in a pilot-scale, full lift, hypolimnetic aerator. Journal of Environmental Engineering and Science. 2013;8(1):11-22. doi:10.1680/jees.2013.0002

BibTeX
@article{Ashley2013,
  author = {Ashley, K.I. and Mavinic, D.S. and Hall, K.J.},
  title = {Effect of orifice diameter, depth of air injection, and air flow rate on oxygen transfer in a pilot-scale, full lift, hypolimnetic aerator},
  journal = {Journal of Environmental Engineering and Science},
  year = {2013},
  volume = {8},
  number = {1},
  pages = {11--22},
  doi = {10.1680/jees.2013.0002}
}
Kostenlos starten →