EUVIMEDEUVIMED entdecken
Crossref

USE OF VISCOELASTIC COAGULATION TESTING IN MEGACHIROPTERA (PTEROPUS HYPOMELANUS AND PTEROPUS VAMPYRUS) REVEALS HIGH VARIABILITY IN CLOT KINETICS

Emily E Brenner, Amy B Alexander, Leonel A Londoño, Nicole I Stacy, Sarah E Crevasse, Jorge A Hernandez, James F X Wellehan

Journal of Zoo and Wildlife Medicine · 13.06.2024 · 55 (2) · 393-403

DOI: 10.1638/2023-0037 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Zoo and Wildlife Medicine, erschienen am 13.06.2024. Verfasst von Emily E Brenner und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Comparative, Diagnostic, and Population Medicine, University of Florida, College of Veterinary Medicine, Gainesville, FL 32610-0126, US…. Hauptthemen laut MEDLINE: Chiroptera. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 46 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Megachiroptera is a mammalian suborder that includes old world fruit bats. Common clinical problems among captive Megachiroptera, such as liver disease (e.g., iron storage disease), kidney disease (e.g., protein-losing nephropathy), and heart disease (e.g., dilated cardiomyopathy), carry elevated risk for hemostatic derangements. The assessment of viscoelastic coagulation assays, however, has not yet been reported in bats. The main objective of the study was to describe viscoelastography data using the Viscoelastic Coagulation Monitor (VCM) Vet in captive large flying foxes (Pteropus vampyrus) (n = 20) and variable flying foxes (Pteropus hypomelanus) (n = 10). Additional objectives were to compare viscoelastic and clotting parameters (1) between healthy P. vampyrus and P. hypomelanus bats and (2) between untreated bats and those treated with meloxicam or aspirin, and (3) to examine relationships between activated partial thromboplastin time (aPTT) and potentially homologous viscoelastic parameters clotting time (CT) and clot formation time (CFT). The results showed marked variability among clinically normal bats. The intrinsic pathway, as measured by aPTT, had prolonged times compared with most terrestrial mammals, but similar times to birds, marine mammals, and sea turtles. A search of P. vampyrus genome found stop codons present in two exons of the factor XI gene; alterations in factor XI expression would be expected to alter intrinsic coagulation. Because of the high variability, no statistically significant findings were noted in the secondary objectives. Correlation between aPTT and CT or CFT was not strong (rs = 0.406 or 0.192, respectively). The results from this study suggest that clot kinetics vary widely among Megachiroptera when using the VCM Vet with untreated blood. A prolonged intrinsic coagulation pathway, as has been found in other megachiropteran species, and activation of the extrinsic coagulation pathway during venipuncture may be responsible for the inconsistent results.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ChiropteraAnimalsBlood CoagulationBlood Coagulation TestsFemaleMale

Autor:innen und Institutionen

  • Department of Comparative, Diagnostic, and Population Medicine, University of Florida, College of Veterinary Medicine, Gainesville, FL 32610-0126, USA, emily.e.brenner@gmail.com.
  • Department of Comparative, Diagnostic, and Population Medicine, University of Florida, College of Veterinary Medicine, Gainesville, FL 32610-0126, USA.
  • Department of Small Animal Clinical Sciences, University of Florida, College of Veterinary Medicine, Gainesville, FL 32610-0126, USA.
  • Department of Large Animal Clinical Sciences, University of Florida, College of Veterinary Medicine, Gainesville, FL 32610-0126, USA.

Zitieren

APA

Brenner, E. E., Alexander, A. B., Londoño, L. A., Stacy, N. I., Crevasse, S. E., Hernandez, J. A., & Wellehan, J. F. X. (2024). USE OF VISCOELASTIC COAGULATION TESTING IN MEGACHIROPTERA (PTEROPUS HYPOMELANUS AND PTEROPUS VAMPYRUS) REVEALS HIGH VARIABILITY IN CLOT KINETICS. Journal of Zoo and Wildlife Medicine, 55(2), 393-403. https://doi.org/10.1638/2023-0037

Vancouver

Brenner EE, Alexander AB, Londoño LA, Stacy NI, Crevasse SE, Hernandez JA, et al. USE OF VISCOELASTIC COAGULATION TESTING IN MEGACHIROPTERA (PTEROPUS HYPOMELANUS AND PTEROPUS VAMPYRUS) REVEALS HIGH VARIABILITY IN CLOT KINETICS. Journal of Zoo and Wildlife Medicine. 2024;55(2):393-403. doi:10.1638/2023-0037

BibTeX
@article{Brenner2024,
  author = {Brenner, Emily E and Alexander, Amy B and Londoño, Leonel A and Stacy, Nicole I and Crevasse, Sarah E and Hernandez, Jorge A and Wellehan, James F X},
  title = {USE OF VISCOELASTIC COAGULATION TESTING IN MEGACHIROPTERA (PTEROPUS HYPOMELANUS AND PTEROPUS VAMPYRUS) REVEALS HIGH VARIABILITY IN CLOT KINETICS},
  journal = {Journal of Zoo and Wildlife Medicine},
  year = {2024},
  volume = {55},
  number = {2},
  pages = {393--403},
  doi = {10.1638/2023-0037}
}
Kostenlos starten →