EUVIMEDEUVIMED entdecken
Crossref

INVESTIGATION OF A POINT-OF-CARE VISCOELASTIC COAGULATION MONITOR AND ITS COMPARISON TO THROMBOELASTOGRAPHY IN CLINICALLY HEALTHY AFRICAN ELEPHANTS (LOXODONTA AFRICANA)

Ashlyn C Heniff, Alex M Lynch, Laura K Ruterbories, Larry J Minter, Timothy A Georoff, Julie A Balko

Journal of Zoo and Wildlife Medicine · 05.03.2024 · 55 (1) · 164-172

DOI: 10.1638/2022-0158 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Zoo and Wildlife Medicine, erschienen am 05.03.2024. Verfasst von Ashlyn C Heniff und 5 weiteren Autor:innen. Beteiligte Einrichtung: College of Veterinary Medicine, Departments of Clinical Sciences, North Carolina State University, Raleigh, NC 27606, USA. Hauptthemen laut MEDLINE: Elephants, Herpesviridae. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 54 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Elephant endotheliotropic herpesvirus (EEHV) can induce fatal hemorrhagic disease (HD) in African elephants (Loxodonta africana). Once clinical signs develop, progression is rapid, even with aggressive treatment. There is a critical need to develop point-of-care diagnostic tests to aid in identification of EEHV-HD prior to the onset of overt clinical signs. Study objectives were to investigate a novel, point-of-care viscoelastic coagulation monitor (VCM Vet), compare the results to thromboelastography (TEG), and report traditional hemostatic analytes in adult African elephants. Whole blood was collected from seven clinically healthy elephants (four females and three males, 18–47 yr) and analyzed in duplicate via VCM Vet and kaolin-activated TEG 1–3 and 30 min following collection, respectively. Separated plasma was frozen for ancillary coagulation testing. Both analyses generated quantifiable clotting reactions with variables (median [range]) describing clot formation rate (VCM Vet, clot time = 682 s [530–987 s], clot formation time = 244 s [186–744 s], Alpha = 40° [14–47°]; TEG, reaction time = 6.2 min [3.7–11.8 min], kinetic time = 1.3 min [0.9–2.6 min], Alpha = 70° [57–77°]), clot strength (VCM Vet, maximum clot formation = 34 units [20–45 units]; TEG, maximum amplitude = 75 mm [69–80 mm], shear elastic modulus strength = 14.7 Kdynes/s [11.3–19.5 Kdynes/s]), and clot lysis (VCM Vet, lysis index at 30 min = 100% [100–99%], lysis index at 45 min = 98% [95–100%]; TEG, lysis index at 30 min = 0% [0–0.4%], lysis index at 60 min = 1.4% [0–2.6%]) recorded. Additional testing (median [range]) included D-dimer concentration (33 ng/ml [28–94 ng/ml]), prothrombin time (12.4 s [12.2–13.2 s]), activated partial thromboplastin time (17.2 s [14.2–18.8 s]), and fibrinogen concentration (297 [282–383] mg/dL). Tracings generated by VCM Vet and TEG were clinically similar, and there was visual agreement and minimal difference between quantitative variables for duplicate tests. VCM Vet is a promising, user-friendly tool for use in identification and management of coagulopathies in African elephants.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ElephantsHerpesviridaeMaleFemaleAnimalsThrombelastographyPoint-of-Care SystemsBlood CoagulationBlood Coagulation Tests

Autor:innen und Institutionen

  • College of Veterinary Medicine, Departments of Clinical Sciences, North Carolina State University, Raleigh, NC 27606, USA.
  • North Carolina Zoo, Asheboro, NC 27205, USA.
  • Molecular Biomedical Sciences, North Carolina State University, Raleigh, NC 27606, USA, jabalko@ncsu.edu.

Zitieren

APA

Heniff, A. C., Lynch, A. M., Ruterbories, L. K., Minter, L. J., Georoff, T. A., & Balko, J. A. (2024). INVESTIGATION OF A POINT-OF-CARE VISCOELASTIC COAGULATION MONITOR AND ITS COMPARISON TO THROMBOELASTOGRAPHY IN CLINICALLY HEALTHY AFRICAN ELEPHANTS (LOXODONTA AFRICANA). Journal of Zoo and Wildlife Medicine, 55(1), 164-172. https://doi.org/10.1638/2022-0158

Vancouver

Heniff AC, Lynch AM, Ruterbories LK, Minter LJ, Georoff TA, Balko JA. INVESTIGATION OF A POINT-OF-CARE VISCOELASTIC COAGULATION MONITOR AND ITS COMPARISON TO THROMBOELASTOGRAPHY IN CLINICALLY HEALTHY AFRICAN ELEPHANTS (LOXODONTA AFRICANA). Journal of Zoo and Wildlife Medicine. 2024;55(1):164-172. doi:10.1638/2022-0158

BibTeX
@article{Heniff2024,
  author = {Heniff, Ashlyn C and Lynch, Alex M and Ruterbories, Laura K and Minter, Larry J and Georoff, Timothy A and Balko, Julie A},
  title = {INVESTIGATION OF A POINT-OF-CARE VISCOELASTIC COAGULATION MONITOR AND ITS COMPARISON TO THROMBOELASTOGRAPHY IN CLINICALLY HEALTHY AFRICAN ELEPHANTS (LOXODONTA AFRICANA)},
  journal = {Journal of Zoo and Wildlife Medicine},
  year = {2024},
  volume = {55},
  number = {1},
  pages = {164--172},
  doi = {10.1638/2022-0158}
}