Comparison of a viscoelastic point‐of‐care coagulation monitor with thromboelastography in sick dogs with hemostatic abnormalities
Veterinary Clinical Pathology · 2023
DOI: 10.1111/vcp.13198 ↗Kurz gefasst
Fachartikel in der Zeitschrift Veterinary Clinical Pathology, 2023. Verfasst von Yekaterina Buriko und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Sciences and Advanced Medicine, Veterinary Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania, USA. Hauptthemen laut MEDLINE: Hemostatics, Blood Coagulation Disorders, Dog Diseases. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 40 Literaturangaben. Gefördert von: Entegrion.
Abstract (Originalsprache)
Background
Viscoelastic coagulation monitor (VCM‐Vet) is a point‐of‐care device that has been used to characterize hemostatic abnormalities in sick pets but has not been validated in veterinary patients.
Objectives
We aimed to compare VCM‐Vet and thromboelastography (TEG) in sick dogs with suspected disorders of hemostasis.
Methods
Duplicate VCM‐Vet tests using untreated native blood performed concurrently on two VCM‐Vet machines, and simultaneous TEG tests were performed (one citrated native (CN), and one activated with tissue factor (TF) at a 1:3600 dilution). Each VCM‐Vet result was compared with both TF‐activated and CN TEG.
Results
Fifty‐three dogs were enrolled. Eleven cases displayed apparent hyperfibrinolysis. Spearman correlation coefficients for individual VCM‐Vet devices and CN and TF TEG were obtained between R and CT values and ranged from 0.21 to 0.27, CFT and K ( r = 0.60–0.67), angles ( r = 0.51–0.62), and MCF and MA ( r = 0.85–0.87). Comparison of the two VCM‐Vet devices displayed positive correlations for all clot formation parameters with Lin's concordance correlation coefficients of 0.75–0.95. Variable lysis parameter agreement existed between the VCM‐Vet devices and VCM‐Vet and TEG. When samples were classified as hypercoagulable or coagulopathic, VCM‐Vet had a low positive predictive value (17–33%) for the detection of hypercoagulable states and a moderate negative predictive value (64–74%) for the detection of coagulopathy as defined by TEG.
Conclusions
VCM‐Vet and TEG had variable correlations in clot formation values and a strong correlation for final clot strength. More information is needed to make conclusions about the lysis parameters. Artifact in the fibrinolysis portion of the test can confound the interpretation of VCM‐Vet results.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Clinical Sciences and Advanced Medicine, Veterinary Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania, USA.
ORCID-Profile: Yekaterina Buriko, Nolan V Chalifoux
Förderung
- Entegrion
Zitieren
APA
Buriko, Y., Chalifoux, N. V., Clarkin-Breslin, R., & Silverstein, D. C. (2023). Comparison of a viscoelastic point‐of‐care coagulation monitor with thromboelastography in sick dogs with hemostatic abnormalities. Veterinary Clinical Pathology. https://doi.org/10.1111/vcp.13198
Vancouver
Buriko Y, Chalifoux NV, Clarkin-Breslin R, Silverstein DC. Comparison of a viscoelastic point‐of‐care coagulation monitor with thromboelastography in sick dogs with hemostatic abnormalities. Veterinary Clinical Pathology. 2023. doi:10.1111/vcp.13198
BibTeX
@article{Buriko2023,
author = {Buriko, Yekaterina and Chalifoux, Nolan V and Clarkin-Breslin, Rachel and Silverstein, Deborah C},
title = {Comparison of a viscoelastic point‐of‐care coagulation monitor with thromboelastography in sick dogs with hemostatic abnormalities},
journal = {Veterinary Clinical Pathology},
year = {2023},
doi = {10.1111/vcp.13198}
}
EUVIMED