Biomechanical effect of inclined implants in fixed prosthesis: strain and stress analysis
Revista de Odontologia da UNESP · 13.08.2018 · 47 (4) · 237-243
DOI: 10.1590/1807-2577.05418 ↗Kurz gefasst
Fachartikel in der Zeitschrift Revista de Odontologia da UNESP, online erschienen am 13.08.2018. Verfasst von Vinícius Anéas RODRIGUES und 4 weiteren Autor:innen. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 28 Literaturangaben.
Abstract (Originalsprache)
Introduction
Implant inclinations can be corrected using mini abutments at different angulations.
Objective
To analyze the influence of external hexagon implants in different inclinations (3 levels) on the microstrain distribution generated around three implants.
Method
A geometric bone model was created through Rhinoceros CAD software (version 5.0 SR8, Mcneel North America, Seattle, WA, USA). Three implants (4.1 × 13 mm) were modeled and inserted inside the substrate at three different inclinations: 0º, 17º and 30º. Next, all groups received mini conical abutments, fixation screws and a simplified prosthesis. The final geometry was exported in STEP format to analysis software and all materials were considered homogeneous, isotropic and linearly elastic. An axial load (300N) was applied on the center of the prosthesis. An in vitro study was conducted with same conditions and groups for validating the tridimentional model.
Result
Stress was concentrated on the external area of the implants, in contact with the cortical bone and external hexagon. For the bone simulator, the strain increased in the peri-implant region according to the increase in the implant’s inclination. The difference between groups was significant (p = 0.000). The 30º group presented higher stress and strain concentration.
Conclusion
The microstrain and stress increase around implants directly proportional to the increase of the installation angle.
Zitieren
APA
RODRIGUES, V. A., TRIBST, J. P. M., SANTIS, L. R., BORGES, A. L. S., & NISHIOKA, R. S. (2018). Biomechanical effect of inclined implants in fixed prosthesis: strain and stress analysis. Revista de Odontologia da UNESP, 47(4), 237-243. https://doi.org/10.1590/1807-2577.05418
Vancouver
RODRIGUES VA, TRIBST JPM, SANTIS LR, BORGES ALS, NISHIOKA RS. Biomechanical effect of inclined implants in fixed prosthesis: strain and stress analysis. Revista de Odontologia da UNESP. 2018;47(4):237-243. doi:10.1590/1807-2577.05418
BibTeX
@article{RODRIGUES2018,
author = {RODRIGUES, Vinícius Anéas and TRIBST, João Paulo Mendes and SANTIS, Leandro Ruivo and BORGES, Alexandre Luiz Souto and NISHIOKA, Renato Sussumu},
title = {Biomechanical effect of inclined implants in fixed prosthesis: strain and stress analysis},
journal = {Revista de Odontologia da UNESP},
year = {2018},
volume = {47},
number = {4},
pages = {237--243},
doi = {10.1590/1807-2577.05418}
}
EUVIMED