EUVIMEDDescoperă EUVIMED
Open access · CC BY 4.0

EXPERIMENTAL EVALUATION OF THE PERFORMANCE OF THE FLANGE OF A SOLID COMPOSITE LINERLESS CRYOGENIC PIPELINE USING THE METHOD OF A CONSTRUCTIVELY SIMILAR SAMPLE

Tamara Manko, Oleksandr Litot, Valentyn Murashko

Journal of Rocket-Space Technology · 2026-04-20 · 35 (1) · 42-49

DOI: 10.15421/452560 ↗

At a glance

Journal article in Journal of Rocket-Space Technology, published online on 2026-04-20. Written by Tamara Manko and 2 co-authors. 14 references. The full text is freely available (open access, CC BY 4.0).

RezumatDate bibliograficeCiteRelated studies

Abstract (original language)

The article presents the results of an experimental performance assessment of the composite linerless cryogenic pipeline flange designed for a rocket launch vehicle using the structurally similar sample method. The study is aimed at confirming the strength, rigidity and tightness of the flange assembly under conditions of internal overpressure and cryogenic temperatures, taking into account multiple refueling cycles. The object of the study is a flange made of carbon fiber based on carbon fabric type 3752 and epoxy EDT-10P, integrated into the design of a linerless shell of carbon fiber IMS65 and Huntsman matrix. The work examines in detail the technology for manufacturing a structurally similar sample, which includes the formation of a multilayer package with the orientation of the layers with [0/22.5/45/67.5/90]n scheme, pressing in a rigid metal mold, thermal polymerization in a controlled temperature cycle and subsequent mechanical processing on numerically controlled machines using a vacuum table. To predict the stress-strain state, numerical modeling was used using the finite element method, taking into account the orthotropic properties of the composite. Calculations were performed using the Autodesk Fusion 360 and CATIA Composites Design software packages. The load was modeled with an equivalent internal pressure of 1.95 MPa. The experimental part included hydraulic tests with water, testing with gaseous helium, and tests under cryogenic temperatures using liquid nitrogen. The parameters were monitored by pressure sensors LG 415/40, MPM-489-500 and measuring system LTR 212. The tightness was assessed by the saponification method and helium leak detector. The results obtained confirmed the compliance of the flange with the requirements for strength and tightness at an operating pressure of 1.95 MPa. The absence of structural damage, joint opening and loss of tightness after testing cycles was established. The effectiveness of the method of structurally similar sample for testing structural and technological solutions of flange assemblies of all-composite cryogenic pipelines was proven.

Cite

APA

Manko, T., Litot, O., & Murashko, V. (2026). EXPERIMENTAL EVALUATION OF THE PERFORMANCE OF THE FLANGE OF A SOLID COMPOSITE LINERLESS CRYOGENIC PIPELINE USING THE METHOD OF A CONSTRUCTIVELY SIMILAR SAMPLE. Journal of Rocket-Space Technology, 35(1), 42-49. https://doi.org/10.15421/452560

Vancouver

Manko T, Litot O, Murashko V. EXPERIMENTAL EVALUATION OF THE PERFORMANCE OF THE FLANGE OF A SOLID COMPOSITE LINERLESS CRYOGENIC PIPELINE USING THE METHOD OF A CONSTRUCTIVELY SIMILAR SAMPLE. Journal of Rocket-Space Technology. 2026;35(1):42-49. doi:10.15421/452560

BibTeX
@article{Manko2026,
  author = {Manko, Tamara and Litot, Oleksandr and Murashko, Valentyn},
  title = {EXPERIMENTAL EVALUATION OF THE PERFORMANCE OF THE FLANGE OF A SOLID COMPOSITE LINERLESS CRYOGENIC PIPELINE USING THE METHOD OF A CONSTRUCTIVELY SIMILAR SAMPLE},
  journal = {Journal of Rocket-Space Technology},
  year = {2026},
  volume = {35},
  number = {1},
  pages = {42--49},
  doi = {10.15421/452560}
}
Start for free →