Übersichtsarbeit in der Zeitschrift Interventional Cardiology: Reviews, Research, Resources, online erschienen am 26.05.2023. Verfasst von Yasar Sattar und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, West Virginia University Morgantown, WV, US. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Background
Radiation exposure is an occupational hazard for interventional cardiologists and cardiac catheterisation laboratory staff that can manifest with serious long-term health consequences. Personal protective equipment, including lead jackets and glasses, is common, but the use of radiation protective lead caps is inconsistent.
Methods
A systematic review qualitative assessment of five observational studies using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines protocol was performed.
Results
It was concluded that lead caps significantly reduce radiation exposure to the head, even when a ceiling-mounted lead shield was present.
Conclusion
Although newer protective systems are being studied and introduced, tools, such as lead caps, need to be strongly considered and employed in the catheterisation laboratory as mainstay personal protective equipment.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, West Virginia University Morgantown, WV, US.
- Department of Medicine, CMH Lahore Medical College and Institute of Dentistry Lahore, Punjab, Pakistan.
- Department of Internal Medicine, BronxCare Health System New York, NY, US.
- Department of Cardiology, Hackensack University Medical Centre NJ, US.
- Department of Internal Medicine, University of Nevada, Kirk Kerkorian School of Medicine Las Vegas, NV, US.
- Department of Cardiology, Boston University Boston, MA, US.
Zitieren
APA
Sattar, Y., Sengodan, P. M., Cheema, M. S., Javed, N., Ashraf, S., Fakhra, S., Alharbi, A., Syed, M., Alam, M., Elgendy, I. Y., Haleem, A., Kawsara, A., Alraies, M. C., & Daggubati, R. (2023). Lead Cap Use in Interventional Cardiology: Time to Protect Our Head in the Cardiac Catheterisation Laboratory?. Interventional Cardiology: Reviews, Research, Resources, 18. https://doi.org/10.15420/icr.2023.10
Vancouver
Sattar Y, Sengodan PM, Cheema MS, Javed N, Ashraf S, Fakhra S, et al. Lead Cap Use in Interventional Cardiology: Time to Protect Our Head in the Cardiac Catheterisation Laboratory?. Interventional Cardiology: Reviews, Research, Resources. 2023;18. doi:10.15420/icr.2023.10
BibTeX
@article{Sattar2023,
author = {Sattar, Yasar and Sengodan, Prasanna M and Cheema, Mustafa Sajjad and Javed, Nismat and Ashraf, Shoaib and Fakhra, Sadaf and Alharbi, Anas and Syed, Moinuddin and Alam, Mahboob and Elgendy, Islam Y and Haleem, Affan and Kawsara, Akram and Alraies, M Chadi and Daggubati, Ramesh},
title = {Lead Cap Use in Interventional Cardiology: Time to Protect Our Head in the Cardiac Catheterisation Laboratory?},
journal = {Interventional Cardiology: Reviews, Research, Resources},
year = {2023},
volume = {18},
doi = {10.15420/icr.2023.10}
}
EUVIMED