Fachartikel in der Zeitschrift Cardiac Failure Review, online erschienen am 02.11.2026. Verfasst von Cathy West und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Royal Brisbane and Women's Hospital Brisbane, Australia. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Background
Transthoracic echocardiography (TTE) is essential for modern cardiac diagnostics, yet it is difficult to access in remote areas. Remotely operated robotic-assisted ultrasound may enable access to services in rural and remote locations, while also improving ergonomics for the sonographer. This study evaluated the safety, usability and patient satisfaction of a novel robotic ultrasound assistance tool (RUAT).
Methods
This open-label, single-site, single-arm clinical trial enrolled adult participants who had recently completed a standard manual echocardiogram. A trained sonographer performed a robot-assisted TTE from a dedicated workstation in the same room as the patient. Endpoints included safety measured by adverse events, technical and clinical usability, and patient satisfaction using surveys about the participants’ experience.
Results
The trial cohort (n=30; mean age 62.9 ± 17.5 years; 70% men) all successfully completed the robot-assisted TTE and the patient satisfaction survey. There were no adverse events or adverse device effects. The functional verification checklist supporting technical usability demonstrated an average usability rate of 96.9% (95% CI [98.9–100.0]), with a 100% rate across 10 of 12 metrics. The sonographer’s review of the acquired robotic images measured the clinical usability and 29 of 30 examinations met acceptable diagnostic standards (96.7%; 95% CI [88.1–100.0]). The mean participant satisfaction score was 8.3 out of 10, with 96.7% scoring ≥6.
Conclusion
The RUAT demonstrated high technical and clinical usability, as well as high acceptance by participants. These findings indicate that robot-assisted TTE is a viable strategy to enhance remote access to TTE services.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, Royal Brisbane and Women's Hospital Brisbane, Australia.
- Faculty of Health, Medicine and Behavioural Sciences, University of Queensland Brisbane, Australia.
ORCID-Profile: Cathy West, Kristyan Guppy-Coles, James W Armstrong, Adam Scott, John J Atherton
Zitieren
APA
West, C., Guppy-Coles, K., Armstrong, J. W., Johnstone, M., Scott, A., & Atherton, J. J. (2026). Safety and Usability of a Novel, Robotic Assistance System for Echocardiographic Examination. Cardiac Failure Review. https://doi.org/10.15420/cfr.2026.49
Vancouver
West C, Guppy-Coles K, Armstrong JW, Johnstone M, Scott A, Atherton JJ. Safety and Usability of a Novel, Robotic Assistance System for Echocardiographic Examination. Cardiac Failure Review. 2026. doi:10.15420/cfr.2026.49
BibTeX
@article{West2026,
author = {West, Cathy and Guppy-Coles, Kristyan and Armstrong, James W and Johnstone, Matthew and Scott, Adam and Atherton, John J},
title = {Safety and Usability of a Novel, Robotic Assistance System for Echocardiographic Examination},
journal = {Cardiac Failure Review},
year = {2026},
doi = {10.15420/cfr.2026.49}
}
EUVIMED