EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Safety and Usability of a Novel, Robotic Assistance System for Echocardiographic Examination

Cathy West iD, Kristyan Guppy-Coles iD, James W Armstrong iD, Matthew Johnstone, Adam Scott iD, John J Atherton iD

Cardiac Failure Review · 02.11.2026

DOI: 10.15420/cfr.2026.49 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Cardiac Failure Review, online erschienen am 02.11.2026. Verfasst von Cathy West und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Royal Brisbane and Women's Hospital Brisbane, Australia. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Transthoracic echocardiography (TTE) is essential for modern cardiac diagnostics, yet it is difficult to access in remote areas. Remotely operated robotic-assisted ultrasound may enable access to services in rural and remote locations, while also improving ergonomics for the sonographer. This study evaluated the safety, usability and patient satisfaction of a novel robotic ultrasound assistance tool (RUAT).

Methods

This open-label, single-site, single-arm clinical trial enrolled adult participants who had recently completed a standard manual echocardiogram. A trained sonographer performed a robot-assisted TTE from a dedicated workstation in the same room as the patient. Endpoints included safety measured by adverse events, technical and clinical usability, and patient satisfaction using surveys about the participants’ experience.

Results

The trial cohort (n=30; mean age 62.9 ± 17.5 years; 70% men) all successfully completed the robot-assisted TTE and the patient satisfaction survey. There were no adverse events or adverse device effects. The functional verification checklist supporting technical usability demonstrated an average usability rate of 96.9% (95% CI [98.9–100.0]), with a 100% rate across 10 of 12 metrics. The sonographer’s review of the acquired robotic images measured the clinical usability and 29 of 30 examinations met acceptable diagnostic standards (96.7%; 95% CI [88.1–100.0]). The mean participant satisfaction score was 8.3 out of 10, with 96.7% scoring ≥6.

Conclusion

The RUAT demonstrated high technical and clinical usability, as well as high acceptance by participants. These findings indicate that robot-assisted TTE is a viable strategy to enhance remote access to TTE services.

Schlagwörter

Stichwörter der Autor:innen

Robot-assisted echocardiographycollaborative robotmedical devicesremote ultrasoundsafety and usabilitysonographer ergonomics

Autor:innen und Institutionen

  • Department of Cardiology, Royal Brisbane and Women's Hospital Brisbane, Australia.
  • Faculty of Health, Medicine and Behavioural Sciences, University of Queensland Brisbane, Australia.

ORCID-Profile: Cathy West, Kristyan Guppy-Coles, James W Armstrong, Adam Scott, John J Atherton

Zitieren

APA

West, C., Guppy-Coles, K., Armstrong, J. W., Johnstone, M., Scott, A., & Atherton, J. J. (2026). Safety and Usability of a Novel, Robotic Assistance System for Echocardiographic Examination. Cardiac Failure Review. https://doi.org/10.15420/cfr.2026.49

Vancouver

West C, Guppy-Coles K, Armstrong JW, Johnstone M, Scott A, Atherton JJ. Safety and Usability of a Novel, Robotic Assistance System for Echocardiographic Examination. Cardiac Failure Review. 2026. doi:10.15420/cfr.2026.49

BibTeX
@article{West2026,
  author = {West, Cathy and Guppy-Coles, Kristyan and Armstrong, James W and Johnstone, Matthew and Scott, Adam and Atherton, John J},
  title = {Safety and Usability of a Novel, Robotic Assistance System for Echocardiographic Examination},
  journal = {Cardiac Failure Review},
  year = {2026},
  doi = {10.15420/cfr.2026.49}
}
Kostenlos starten →