RESEARCH TO THE POSSIBILITY OF CONVERTING THE INTER-STATE ELECTRICITY TRANSMISSION LINE WESTERN UKRAINE – SZABOLCSBÁNYA TO NOMINAL VOLTAGE OF 400 KV
Praci Institutu elektrodinamiki Nacionalanoi akademii nauk Ukraini · 14.05.2026 · 2026 (73) · 31-39
DOI: 10.15407/publishing2026.73.031 ↗Kurz gefasst
Fachartikel in der Zeitschrift Praci Institutu elektrodinamiki Nacionalanoi akademii nauk Ukraini, online erschienen am 30.04.2026. Verfasst von T. Katsadze und 1 weiteren Autor:innen. Die Arbeit nennt 10 Literaturangaben.
Abstract (Originalsprache)
The article discusses the technical and energy feasibility of converting the inter-state overhead power line Zakhidnou-krainska – Szabolcsbaka from a nominal voltage of 750 kV to 400 kV within the dimensions of the existing line. The relevance of the study is determined by the need to improve the efficiency of the unified energy system of Ukraine, strengthen its stability, and integrate it with the energy market of the European Union. One of the key elements of the interstate energy intersection is the 750 kV Zakhidnoukrainska – Szabolcsbaka line, whose operating modes are char-acterized by significant power losses due to corona discharge. The paper presents the results of modeling the Ukraine-Hungary transit operating modes, performed in the PowerFactory software environment for two line operation options – at 750 kV and 400 kV. A comparative analysis of active power losses (Joule losses and corona losses) was performed, taking into account the influence of weather conditions (clear weather, rain, snow, frost) and different load levels. The calculations showed that at a voltage of 750 kV, corona discharge losses prevail over Joule losses, especially in unfa-vorable weather conditions, while in the 400 kV option, the share of corona losses is significantly reduced, but Joule losses increase. It has been established that reducing the nominal voltage to 400 kV is energy efficient only at relatively low line loads – up to 200 MW in clear weather, up to 400 MW during snow, 750 MW during rain, and 950 MW during frost. For larger power flows, it is advisable to maintain a voltage of 750 kV, as the total losses are lower in this case. Ref. 10, fig. 6, tables 4.
Zitieren
APA
Katsadze, T., & Luhin, D. (2026). RESEARCH TO THE POSSIBILITY OF CONVERTING THE INTER-STATE ELECTRICITY TRANSMISSION LINE WESTERN UKRAINE – SZABOLCSBÁNYA TO NOMINAL VOLTAGE OF 400 KV. Praci Institutu elektrodinamiki Nacionalanoi akademii nauk Ukraini, 2026(73), 31-39. https://doi.org/10.15407/publishing2026.73.031
Vancouver
Katsadze T, Luhin D. RESEARCH TO THE POSSIBILITY OF CONVERTING THE INTER-STATE ELECTRICITY TRANSMISSION LINE WESTERN UKRAINE – SZABOLCSBÁNYA TO NOMINAL VOLTAGE OF 400 KV. Praci Institutu elektrodinamiki Nacionalanoi akademii nauk Ukraini. 2026;2026(73):31-39. doi:10.15407/publishing2026.73.031
BibTeX
@article{Katsadze2026,
author = {Katsadze, T. and Luhin, D.},
title = {RESEARCH TO THE POSSIBILITY OF CONVERTING THE INTER-STATE ELECTRICITY TRANSMISSION LINE WESTERN UKRAINE – SZABOLCSBÁNYA TO NOMINAL VOLTAGE OF 400 KV},
journal = {Praci Institutu elektrodinamiki Nacionalanoi akademii nauk Ukraini},
year = {2026},
volume = {2026},
number = {73},
pages = {31--39},
doi = {10.15407/publishing2026.73.031}
}