On the optimal time points for assessing the cortisol response in the high-dose ACTH stimulation test – a literature review

Karlijn Koops, Annenienke C van de Ven, Michiel N Kerstens, Judith Ma Emmen, Nienke R Biermasz, Annemieke C Heijboer iD, Jacquelien J Hillebrand iD

Journal of Molecular Endocrinology · 18.11.2026

DOI: 10.1530/jme-26-0058 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Molecular Endocrinology, online erschienen am 18.11.2026. Verfasst von Karlijn Koops und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Laboratory Medicine, Endocrine Laboratory, Amsterdam UMC, Vrije Universiteit Amsterdam, Boelelaan 1117, 1081 HV Amsterdam, The Netherla….

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The high-dose ACTH stimulation test is used to assess adrenal insufficiency. Although the test has a rather simple design, many variables in pretest conditions, performing the test and cortisol methods impact the interpretation of the test result, for which rigid cut-offs were previously used. There is growing attention to standardized work-up and using well-standardized analytical methods and assay-specific cortisol cut-offs. There is less consensus on whether post-stimulation serum cortisol concentrations should be measured at 30 minutes (t30) or 60 minutes (t60) or both. Often the same cortisol cut-off is used for measurements at both time points, even though the continuous cortisol response in this time frame suggests using different cut-offs. We reviewed studies describing cortisol measurements at t30 and t60 during the high-dose AST and studied diagnostic accuracy. We noted that cortisol cut-offs should be specific to the assay used and, when using modern assays, lower than the original 500 or 550 nmol/L. When using a single cut-off for t30 and t60, measurements at the t60 time point showed higher specificity. However, when using time point-specific cortisol cut-offs, the specificity of cortisol measurements at t30 or t60 appeared comparable. In conclusion, serum cortisol measurements at t30 and t60 during the high-dose ACTH stimulation test seem equally accurate. A similar performance may be achieved using either time point alone, provided time point and assay-specific cut-offs are used. It should be noted, however, that the results of the high-dose ACTH stimulation test should always be interpreted within the clinical context.

Schlagwörter

Stichwörter der Autor:innen

ACTH testHPA axisadrenal insufficiencycortisoldynamic testing

Autor:innen und Institutionen

  • Department of Laboratory Medicine, Endocrine Laboratory, Amsterdam UMC, Vrije Universiteit Amsterdam, Boelelaan 1117, 1081 HV Amsterdam, The Netherlands.
  • Department of Laboratory Medicine, Endocrine Laboratory, Amsterdam UMC, University of Amsterdam, Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands.
  • Amsterdam Gastroenterology, Endocrinology & Metabolism Research Institute, 1105 AZ Amsterdam, The Netherlands.
  • Department of Internal Medicine, Division of Endocrinology, Radboud University Medical Center , Nijmegen, The Netherlands.
  • Department of Endocrinology, University Medical Center of Groningen, University of Groningen , Groningen, The Netherlands.
  • Department of Clinical Chemistry and Hematology, Amphia Hospital, Molengracht 21, 4818 CK Breda, The Netherlands.

ORCID-Profile: Annemieke C Heijboer, Jacquelien J Hillebrand

Zitieren

APA

Koops, K., van de Ven, A. C., Kerstens, M. N., Emmen, J. M., Biermasz, N. R., Heijboer, A. C., & Hillebrand, J. J. (2026). On the optimal time points for assessing the cortisol response in the high-dose ACTH stimulation test – a literature review. Journal of Molecular Endocrinology. https://doi.org/10.1530/jme-26-0058

Vancouver

Koops K, van de Ven AC, Kerstens MN, Emmen JM, Biermasz NR, Heijboer AC, et al. On the optimal time points for assessing the cortisol response in the high-dose ACTH stimulation test – a literature review. Journal of Molecular Endocrinology. 2026. doi:10.1530/jme-26-0058

BibTeX
@article{Koops2026,
  author = {Koops, Karlijn and van de Ven, Annenienke C and Kerstens, Michiel N and Emmen, Judith Ma and Biermasz, Nienke R and Heijboer, Annemieke C and Hillebrand, Jacquelien J},
  title = {On the optimal time points for assessing the cortisol response in the high-dose ACTH stimulation test – a literature review},
  journal = {Journal of Molecular Endocrinology},
  year = {2026},
  doi = {10.1530/jme-26-0058}
}
Kostenlos starten →