Factors associated with analytical errors in blood chemistry tests

Hyunjung Kim, Soo Jung Lee, Hanwool Cho, Jehoon Lee, Soo-Young Kim, Hae Kyung Lee, Jay Ho Han, HyunYoung Chi, Yeongsic Kim

Clinical Chemistry and Laboratory Medicine (CCLM) · 24.07.2026 · 64 (8) · 1773-1779

DOI: 10.1515/cclm-2026-0153 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Chemistry and Laboratory Medicine (CCLM), online erschienen am 11.05.2026. Verfasst von Hyunjung Kim und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Laboratory Medicine, Uijeongbu St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea. Hauptthemen laut MEDLINE: Blood Chemical Analysis. Die Arbeit nennt 24 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Few studies have systematically evaluated the factors contributing to laboratory errors in the analytical phase. This study analyzed five years of retest data to determine the frequency and characteristics of analytical errors across routine blood chemistry parameters, identify analytes most prone to error, and provide insights for improving test result accuracy.

Methods

We retrospectively reviewed retest records for 23 blood chemistry parameters performed between January 2018 and June 2022. Of 18,015,323 total tests, 58,637 (0.31 %) underwent repeat analysis following delta or panic check alerts. Acceptance limits for repeated measurements were established based on CLIA proficiency testing (PT) regulations and the precision of each analyte. Differences in error rates among analytes were assessed using chi-square tests.

Results

The overall analytical error rate among retested samples was 1.66 %. Carbon dioxide (19.67 %) and ammonia (16.53 %) demonstrated the highest error rates, whereas alanine aminotransferase (0.04 %), albumin (0.09 %), aspartate aminotransferase (0.11 %), sodium (0.18 %), and chloride (0.24 %) showed very low rates. Electrolytes measured using ion-selective electrodes (sodium, potassium, chloride) exhibited lower error rates than those quantified colorimetrically (calcium, phosphate, magnesium). Analytes prone to evaporation or instability, such as carbon dioxide and ammonia, displayed substantial discrepancies upon retesting.

Conclusions

Analytical error rates are influenced by assay complexity, physiological analyte concentration, or specimen stability. Routine retesting may offer limited benefit for high-concentration analytes or methodologically simple assays. In contrast, assays for low-concentration or methodologically complex assays should require more vigilant monitoring. Implementing analyte-specific retesting strategies may enhance laboratory efficiency and improve result accuracy monitoring.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Blood Chemical AnalysisHumansRetrospective Studies

Stichwörter der Autor:innen

analytical erroranalytical phaseblood chemistrylaboratory accuracyretesting

Autor:innen und Institutionen

  • Department of Laboratory Medicine, Uijeongbu St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea.
  • Department of Laboratory Medicine, St. Vincent's Hospital, College of Medicine, The Catholic University of Korea, Suwon, Korea.
  • Department of Laboratory Medicine, Eunpyeong St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea.
  • Samkwang Medical Laboratories, Seoul, Korea.

Zitieren

APA

Kim, H., Lee, S. J., Cho, H., Lee, J., Kim, S. Y., Lee, H. K., Han, J. H., Chi, H., & Kim, Y. (2026). Factors associated with analytical errors in blood chemistry tests. Clinical Chemistry and Laboratory Medicine (CCLM), 64(8), 1773-1779. https://doi.org/10.1515/cclm-2026-0153

Vancouver

Kim H, Lee SJ, Cho H, Lee J, Kim SY, Lee HK, et al. Factors associated with analytical errors in blood chemistry tests. Clinical Chemistry and Laboratory Medicine (CCLM). 2026;64(8):1773-1779. doi:10.1515/cclm-2026-0153

BibTeX
@article{Kim2026,
  author = {Kim, Hyunjung and Lee, Soo Jung and Cho, Hanwool and Lee, Jehoon and Kim, Soo-Young and Lee, Hae Kyung and Han, Jay Ho and Chi, HyunYoung and Kim, Yeongsic},
  title = {Factors associated with analytical errors in blood chemistry tests},
  journal = {Clinical Chemistry and Laboratory Medicine (CCLM)},
  year = {2026},
  volume = {64},
  number = {8},
  pages = {1773--1779},
  doi = {10.1515/cclm-2026-0153}
}
Kostenlos starten →