One copy in one-pot for rapid and accurate SFTSV testing by LAC12b-2M
Clinical Chemistry and Laboratory Medicine (CCLM) · 2026
DOI: 10.1515/cclm-2025-0791 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Chemistry and Laboratory Medicine (CCLM), 2026. Verfasst von Ya Pang und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Laboratory, Center for Gene Diagnosis & Program of Clinical Laboratory, 89674 Zhongnan Hospital of Wuhan University , Wuhan, C…. Hauptthemen laut MEDLINE: Nucleic Acid Amplification Techniques, Phlebovirus, Molecular Diagnostic Techniques. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: National Natural Science Foundation of China, the transformaion project of scientific and technological achievements, Zhongnan Hospital of Wuhan University, the translational medicine and interdisciplinary research joint fund of Zhongnan Hospital of Wuhan University.
Abstract (Originalsprache)
Objectives
Severe fever with thrombocytopenia syndrome virus (SFTSV) is a tick-borne pathogen that can cause a fatality rate as high as 12–50 %, posing a significant threat to public health. SFTSV is prevalent in mountainous and hilly regions with relatively poor medical conditions. Therefore, there is an urgent need to develop a new convenient, rapid and sensitive method for SFTSV detection in low-resource environments.
Methods
We developed a one-pot and visualized method for SFTSV detection using loop-mediated isothermal amplification assisted by CRISPR/Cas12b with G478A/K396A double mutations (LAC12b-2M). The specificity, sensitivity, accuracy and limit of detection (LOD) of LAC12b-2M were evaluated using clinical reverse transcription-quantitative PCR (RT-qPCR) as the reference method, with gradient dilutions of strong positive SFTSV RNA samples and 215 clinical serum samples from two cohorts.
Results
LAC12b-2M is sensitive to detect SFTSV with a LOD of 1 copy/μL at 61 °C within 30 min. Compared to clinical RT-qPCR, LAC12b-2M demonstrated a sensitivity of 98.8 % (82/83), a specificity of 100.0 % (96/96), and an accuracy of 99.4 % (178/179) in cohort 1 (n=179), and an accuracy of 100.0 % in cohort 2 (n=36).
Conclusions
Our LAC12b-2M method holds promise for point-of-care SFTSV testing in different healthcare settings, particularly in low-resource region where SFTSV is prevalent.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Clinical Laboratory, Center for Gene Diagnosis & Program of Clinical Laboratory, 89674 Zhongnan Hospital of Wuhan University , Wuhan, China.
- Department of Clinical Laboratory Medicine, Maternal and Child Health Hospital of Hubei Province, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
- Department of Laboratory Medicine, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
Förderung
- National Natural Science Foundation of China
- the transformaion project of scientific and technological achievements, Zhongnan Hospital of Wuhan University
- the translational medicine and interdisciplinary research joint fund of Zhongnan Hospital of Wuhan University
Zitieren
APA
Pang, Y., Duan, Y., Sun, Y., Zhou, T., Li, A., Ran, R., Hou, H., & Liu, S. M. (2026). One copy in one-pot for rapid and accurate SFTSV testing by LAC12b-2M. Clinical Chemistry and Laboratory Medicine (CCLM). https://doi.org/10.1515/cclm-2025-0791
Vancouver
Pang Y, Duan Y, Sun Y, Zhou T, Li A, Ran R, et al. One copy in one-pot for rapid and accurate SFTSV testing by LAC12b-2M. Clinical Chemistry and Laboratory Medicine (CCLM). 2026. doi:10.1515/cclm-2025-0791
BibTeX
@article{Pang2026,
author = {Pang, Ya and Duan, Yongwei and Sun, Yuehua and Zhou, Tong and Li, Anling and Ran, Ruoxi and Hou, Hongyan and Liu, Song-Mei},
title = {One copy in one-pot for rapid and accurate SFTSV testing by LAC12b-2M},
journal = {Clinical Chemistry and Laboratory Medicine (CCLM)},
year = {2026},
doi = {10.1515/cclm-2025-0791}
}
EUVIMED