EUVIMEDEUVIMED entdecken
Crossref

Paper Microfluidic Platform Using Multiplexed Isothermal Amplification and CRISPR/Cas12a for Aquatic Pathogen Detection

Yuwei Pan, Zhugen Yang iD

ACS Sensors · 2026

DOI: 10.1021/acssensors.6c00719 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Sensors, 2026. Verfasst von Yuwei Pan und 1 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Engineering and Applied Sciences, Cranfield University, CranfieldMK43 0AL, UK. Hauptthemen laut MEDLINE: Nucleic Acid Amplification Techniques, Paper, CRISPR-Cas Systems, Water Microbiology. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 53 Literaturangaben. Gefördert von: Leverhulme Trust, Royal Academy of Engineering, National Centre for Earth Observation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The global health threat posed by microbial contamination of aquatic systems demands feasible pathogen monitoring solutions. However, current detection methods are limited by expensive instrumentation and specialized personnel, which hinders their application in point-of-care testing (POCT). Here, we presented an integrated paper microfluidic platform for spatially multiplexed detection of pathogenic bacteria, including Salmonella, E. coli, C. perfringens, B. cereus, V. parahaemolyticus, S. aureus, and L. monocytogenes, selected due to their epidemiological significance and regulatory relevance in environmental and food safety monitoring. LAMP, RAA-CRISPR, and RPA-CRISPR assays were housed within physically isolated reaction chambers on two-layer chips. An engineered horseradish peroxidase (HRP) cascade-coupled crRNA modification system with DNA-conjugated labels was designed for colorimetric detection. Operation was enabled by solar-powered and portable hardware for incubation and imaging, coupled with a web application for quantitative analysis. Exceptional analytical performance was demonstrated, achieving an LOD of 1 CFU/mL, a dynamic range of 1–107 CFU/mL, high reproducibility (CV <5%), low batch-to-batch variation (<6%), low cost (£2.5 per test), and scalable integration, with a sample-to-answer time of 60 min. Successful field validation in diverse aquatic environments confirmed its practical feasibility, consistent with gold standard PCR (R2 = 0.98). This platform offers a promising POCT solution for public health protection and epidemic monitoring, particularly in resource-limited settings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Nucleic Acid Amplification TechniquesPaperCRISPR-Cas SystemsWater MicrobiologyBacteriaMicrofluidic Analytical TechniquesRapid Diagnostic TestsColorimetryLimit of DetectionMolecular Diagnostic Techniques

Stichwörter der Autor:innen

CRISPR/Cas12aaquatic monitoringisothermal amplificationmultiplexed detectionpaper microfluidic platformpoint-of-care testing (POCT)

Autor:innen und Institutionen

  • Faculty of Engineering and Applied Sciences, Cranfield University, CranfieldMK43 0AL, UK.
  • College of Chemical and Biological Engineering, Zhejiang University, Hangzhou310058, China.

ORCID-Profile: Zhugen Yang

Förderung

  • Leverhulme Trust
  • Royal Academy of Engineering
  • National Centre for Earth Observation

Zitieren

APA

Pan, Y., & Yang, Z. (2026). Paper Microfluidic Platform Using Multiplexed Isothermal Amplification and CRISPR/Cas12a for Aquatic Pathogen Detection. ACS Sensors. https://doi.org/10.1021/acssensors.6c00719

Vancouver

Pan Y, Yang Z. Paper Microfluidic Platform Using Multiplexed Isothermal Amplification and CRISPR/Cas12a for Aquatic Pathogen Detection. ACS Sensors. 2026. doi:10.1021/acssensors.6c00719

BibTeX
@article{Pan2026,
  author = {Pan, Yuwei and Yang, Zhugen},
  title = {Paper Microfluidic Platform Using Multiplexed Isothermal Amplification and CRISPR/Cas12a for Aquatic Pathogen Detection},
  journal = {ACS Sensors},
  year = {2026},
  doi = {10.1021/acssensors.6c00719}
}
Kostenlos starten →