EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Blood pressure estimation using single photoplethysmography signal based on ResNet-BiGRU

Gongwei Fan, Yuhao Pang, Wei Zheng, Min Wang

Biomedical Engineering / Biomedizinische Technik · 2026

DOI: 10.1515/bmt-2025-0285 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Engineering / Biomedizinische Technik, 2026. Verfasst von Gongwei Fan und 3 weiteren Autor:innen. Beteiligte Einrichtung: 12676 College of Ocean, Jiangsu University of Science and Technology , Zhenjiang City, Jiangsu Province, China. Hauptthemen laut MEDLINE: Photoplethysmography, Blood Pressure, Blood Pressure Determination. Die Arbeit nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Conventional cuff-based blood pressure (BP) measurement provides only intermittent readings, whereas photoplethysmography (PPG)-based methods enable continuous and noninvasive monitoring. This study aims to develop a deep learning framework for accurate, cuffless BP estimation using a single PPG signal.

Methods

A hybrid deep neural network, termed ResNet-BiGRU, was developed by integrating residual convolutional blocks with bidirectional gated recurrent units to jointly capture morphological and temporal features. The UCI Cuff-Less Blood Pressure Estimation Dataset (a subset of MIMIC-II), which contains synchronized PPG and arterial blood pressure (ABP) signals from 942 subjects, was used for model training and validation. After applying a 0.5–8 Hz bandpass filter and segmenting into 5 s windows, the data were split 80/20 for training and validation. External evaluation was conducted using the VitalDB dataset, which provides synchronized PPG and ABP recordings from surgical patients under diverse physiological conditions.

Results

The model achieved mean absolute errors (MAE) of 4.78 mmHg for systolic BP (SBP) and 2.98 mmHg for diastolic BP (DBP) on UCI, and 8.15 mmHg for SBP and 4.59 mmHg for DBP on VitalDB.

Conclusions

The ResNet-BiGRU model demonstrates accurate, robust, and generalizable cuffless BP estimation, showing strong potential for wearable health monitoring applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PhotoplethysmographyBlood PressureBlood Pressure DeterminationHumansConvolutional Neural NetworksSignal Processing, Computer-Assisted

Stichwörter der Autor:innen

BiGRUPPG signalResNetattention mechanismblood pressure estimation

Autor:innen und Institutionen

  • 12676 College of Ocean, Jiangsu University of Science and Technology , Zhenjiang City, Jiangsu Province, China.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Fan, G., Pang, Y., Zheng, W., & Wang, M. (2026). Blood pressure estimation using single photoplethysmography signal based on ResNet-BiGRU. Biomedical Engineering / Biomedizinische Technik. https://doi.org/10.1515/bmt-2025-0285

Vancouver

Fan G, Pang Y, Zheng W, Wang M. Blood pressure estimation using single photoplethysmography signal based on ResNet-BiGRU. Biomedical Engineering / Biomedizinische Technik. 2026. doi:10.1515/bmt-2025-0285

BibTeX
@article{Fan2026,
  author = {Fan, Gongwei and Pang, Yuhao and Zheng, Wei and Wang, Min},
  title = {Blood pressure estimation using single photoplethysmography signal based on ResNet-BiGRU},
  journal = {Biomedical Engineering / Biomedizinische Technik},
  year = {2026},
  doi = {10.1515/bmt-2025-0285}
}
Kostenlos starten →