Optimizing arteriovenous fistula (AVF) configurations: a computational study of radial artery deviation and reimplantation (RADAR) and conventional techniques in hemodynamics
Biomedical Engineering / Biomedizinische Technik · 2026
DOI: 10.1515/bmt-2024-0044 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biomedical Engineering / Biomedizinische Technik, 2026. Verfasst von Ning Zhang und 8 weiteren Autor:innen. Beteiligte Einrichtung: 12636 School of Materials Science and Engineering, Zhengzhou University , Zhengzhou, China. Hauptthemen laut MEDLINE: Hemodynamics, Arteriovenous Fistula, Radial Artery, Arteriovenous Shunt, Surgical. Die Arbeit nennt 70 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objectives
Anastomotic stenosis in arteriovenous fistulas (AVFs) is a significant issue for hemodialysis patients. This study uses computational fluid dynamics (CFD) simulations to evaluate the effects of different AVF configurations, comparing the RADAR technique with conventional AVF configurations in terms of hemodynamics, flow disturbances, and wall shear stress (WSS).
Methods
Echo-color Doppler (ECD) imaging and CFD simulations assessed disturbed hemodynamics in different AVF configurations. Large eddy simulations (LES) captured turbulence transition at the anastomosis. Hemodynamic parameters, including velocity distribution, vortex formation, WSS, wall displacement, and stress distribution, were analyzed. A one-way fluid-structure interaction (FSI) approach was used to compute fluid-induced wall forces and assess stress distribution and deformation.
Results
The RADAR configuration showed superior hemodynamic performance with higher blood flow velocity, reduced turbulence, and a more favorable WSS environment, potentially reducing stenosis risk and improving long-term patency. Higher venous inner wall stress in RADAR configurations may aid vascular remodeling.
Conclusions
Optimizing AVF configurations and anastomosis angles can enhance AVF functionality, reduce complications, and improve hemodialysis outcomes for patients with end-stage renal disease. The RADAR technique may improve AVF maturation and reduce complications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- 12636 School of Materials Science and Engineering, Zhengzhou University , Zhengzhou, China.
- National Center for International Research of Micro-Nano Molding Technology, Zhengzhou University, Zhengzhou, China.
- Department of Nephrology, People's Hospital of Zhengzhou University, Zhengzhou, China.
- Fuwai Central China Cardiovascular Hospital, Zhengzhou, China.
- School of Mechanics and Safety Engineering, Zhengzhou University, Zhengzhou, China.
- Key Laboratory of Materials Processing and Mold (Ministry of Education), National Engineering Research Center for Advanced Polymer Processing Technology, Zhengzhou University, Zhengzhou, China.
Zitieren
APA
Zhang, N., Zhang, H., Wang, X., Lu, Y., Li, J., Yan, S., Hou, J., Pan, G., & Li, Q. (2026). Optimizing arteriovenous fistula (AVF) configurations: a computational study of radial artery deviation and reimplantation (RADAR) and conventional techniques in hemodynamics. Biomedical Engineering / Biomedizinische Technik. https://doi.org/10.1515/bmt-2024-0044
Vancouver
Zhang N, Zhang H, Wang X, Lu Y, Li J, Yan S, et al. Optimizing arteriovenous fistula (AVF) configurations: a computational study of radial artery deviation and reimplantation (RADAR) and conventional techniques in hemodynamics. Biomedical Engineering / Biomedizinische Technik. 2026. doi:10.1515/bmt-2024-0044