Synchronisation of wearable inertial measurement units based on magnetometer data
Biomedical Engineering / Biomedizinische Technik · 2023
DOI: 10.1515/bmt-2021-0329 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biomedical Engineering / Biomedizinische Technik, 2023. Verfasst von Andreas Spilz und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechatronics and Medical Engineering, Biomechatronics Research Group, University of Applied Sciences, Ulm, Germany. Hauptthemen laut MEDLINE: Movement, Wearable Electronic Devices. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 20 Literaturangaben. Gefördert von: German Federal Ministry for Economic Affairs and Climate Actions.
Abstract (Originalsprache)
Objectives
Synchronisation of wireless inertial measurement units in human movement analysis is often achieved using event-based synchronisation techniques. However, these techniques lack precise event generation and accuracy. An inaccurate synchronisation could lead to large errors in motion estimation and reconstruction and therefore wrong analysis outputs.
Methods
We propose a novel event-based synchronisation technique based on a magnetic field, which allows sub-sample accuracy. A setup featuring Shimmer3 inertial measurement units is designed to test the approach.
Results
The proposed technique shows to be able to synchronise with a maximum offset of below 2.6 ms with sensors measuring at 100 Hz. The investigated parameters suggest a required synchronisation time of 8 s.
Conclusions
The results indicate a reliable event generation and detection for synchronisation of wireless inertial measurement units. Further research should investigate the temperature changes that the sensors are exposed to during human motion analysis and their influence on the internal time measurement of the sensors. In addition, the approach should be tested using inertial measurement units from different manufacturers to investigate an identified constant offset in the accuracy measurements.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Mechatronics and Medical Engineering, Biomechatronics Research Group, University of Applied Sciences, Ulm, Germany.
ORCID-Profile: Andreas Spilz
Förderung
- German Federal Ministry for Economic Affairs and Climate Actions
Zitieren
APA
Spilz, A., & Munz, M. (2023). Synchronisation of wearable inertial measurement units based on magnetometer data. Biomedical Engineering / Biomedizinische Technik. https://doi.org/10.1515/bmt-2021-0329
Vancouver
Spilz A, Munz M. Synchronisation of wearable inertial measurement units based on magnetometer data. Biomedical Engineering / Biomedizinische Technik. 2023. doi:10.1515/bmt-2021-0329
BibTeX
@article{Spilz2023,
author = {Spilz, Andreas and Munz, Michael},
title = {Synchronisation of wearable inertial measurement units based on magnetometer data},
journal = {Biomedical Engineering / Biomedizinische Technik},
year = {2023},
doi = {10.1515/bmt-2021-0329}
}
EUVIMED