A Prospective, Multicenter Evaluation of Safety and Diagnostic Outcomes With Robotic-Assisted Bronchoscopy

Septimiu Murgu, Alexander C Chen, Christopher R Gilbert, Daniel H Sterman, Damaris Pederson, Samaan Rafeq, Balaji Laxmanan, Michael L Schwiers, Jaime Connelly, Heather L Benz, Kazuhiro Yasufuku, Gerard A Silvestri und 1 weitere

CHEST · 2025-08 · 168 (2) · 539-555

DOI: 10.1016/j.chest.2025.04.022 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift CHEST, 2025-08. Verfasst von Septimiu Murgu und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medicine, Division of Pulmonary and Critical Care Medicine, University of Chicago, Chicago, IL. Electronic address: smurgu@uchicagomedi…. Hauptthemen laut MEDLINE: Bronchoscopy, Image-Guided Biopsy, Lung Neoplasms, Robotic Surgical Procedures. Die Arbeit wurde bisher 60-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Auris Health, Johnson and Johnson, Johnson & Johnson MedTech.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: It remains challenging to safely and reliably biopsy peripheral pulmonary lesions (PPLs). Robotic-assisted bronchoscopy (RAB) is gaining adoption for navigation to PPLs. However, evidence from large studies remains limited. RESEARCH QUESTION: What is the clinical safety, navigational success, and diagnostic yield of RAB for biopsy of PPLs in a broad range of patients in a real-world setting? STUDY DESIGN AND METHODS: This multicenter, prospective, single-arm study enrolled patients aged > 21 years with 8- to 50-mm lung lesions requiring bronchoscopic diagnosis. The primary end point was the incidence of the following device- or procedure-related events: (1) pneumothorax requiring intervention; (2) bleeding requiring intervention; or (3) respiratory failure. Secondary end points included individual components of the primary end point, procedure time, pneumothoraces, radial probe endobronchial ultrasound confirmation, conversion to an alternative biopsy procedure, complications, and diagnostic yield. RESULTS: Among 715 patients at 21 sites, 679 met study criteria and underwent RAB (mean age 68.7 years; 55.4% female; 86.5% White; 77.5% with current/past tobacco use). Mean (range) lesion size was 20.9 (7.0-63.0) mm; median (interquartile range) distance from the pleural surface was 5 (0-16) mm. Most lesions were solid (n = 587 [86.6%]) and within the outer two-thirds of the lung (n = 593 [87.5%]). The primary end point was observed in 26 (3.8%) patients (19 pneumothorax, 7 bleeding, and 0 respiratory failure). Users reported that RAB reached the lesion in 670 (98.7%) of 679 cases, and lesion location was confirmed with radial probe endobronchial ultrasound in 607 (91.7%) of 662 cases; sampling through the bronchoscope was performed in 675 (99.4%) of 679 cases. Prevalence of malignancy was 64.1% through 12 months. Adjudicated diagnostic yield was 61.6% when calculated with the American Thoracic Society/American College of Chest Physicians (CHEST) definition for strict reporting criteria. Sensitivity for malignancy was 78.8%. INTERPRETATION: This multicenter prospective study of RAB-to our knowledge, the largest to date-showed that RAB-guided sampling of PPLs is safe and compares favorably to results from sizable non-robotic bronchoscopy studies. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov; No.: NCT04182815; URL: www. CLINICALTRIALS: gov.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BronchoscopyImage-Guided BiopsyLung NeoplasmsRobotic Surgical ProceduresAgedFemaleHumansMaleMiddle AgedPneumothoraxProspective Studies

Stichwörter der Autor:innen

Monarchbiopsybronchoscopylung cancerlung nodulenavigation bronchoscopyperipheral pulmonary lesionsroboticrobotic bronchoscopy

Autor:innen und Institutionen

  • Department of Medicine, Division of Pulmonary and Critical Care Medicine, University of Chicago, Chicago, IL. Electronic address: smurgu@uchicagomedicine.org.
  • Division of Pulmonology and Critical Care Medicine, St. Louis, MO; Division of Cardiothoracic Surgery, Washington University School of Medicine, St. Louis, MO.
  • Department of Medicine, Division of Pulmonary, Critical Care, Allergy, and Sleep Medicine, Medical University of South Carolina, Charleston, SC.
  • Department of Medicine, Division of Pulmonary, Critical Care, and Sleep Medicine, NYU Grossman School of Medicine, New York, NY.
  • Ethicon, Johnson & Johnson MedTech Surgery, Cincinnati, OH.
  • Interventional Oncology, Johnson & Johnson, New Brunswick, NJ.

Förderung

  • Auris Health
  • Johnson and Johnson
  • Johnson & Johnson MedTech

Zitieren

APA

Murgu, S., Chen, A. C., Gilbert, C. R., Sterman, D. H., Pederson, D., Rafeq, S., Laxmanan, B., Schwiers, M. L., Connelly, J., Benz, H. L., Yasufuku, K., Silvestri, G. A., & TARGET Investigators (2025). A Prospective, Multicenter Evaluation of Safety and Diagnostic Outcomes With Robotic-Assisted Bronchoscopy. CHEST, 168(2), 539-555. https://doi.org/10.1016/j.chest.2025.04.022

Vancouver

Murgu S, Chen AC, Gilbert CR, Sterman DH, Pederson D, Rafeq S, et al. A Prospective, Multicenter Evaluation of Safety and Diagnostic Outcomes With Robotic-Assisted Bronchoscopy. CHEST. 2025;168(2):539-555. doi:10.1016/j.chest.2025.04.022

BibTeX
@article{Murgu2025,
  author = {Murgu, Septimiu and Chen, Alexander C and Gilbert, Christopher R and Sterman, Daniel H and Pederson, Damaris and Rafeq, Samaan and Laxmanan, Balaji and Schwiers, Michael L and Connelly, Jaime and Benz, Heather L and Yasufuku, Kazuhiro and Silvestri, Gerard A and TARGET Investigators, TARGET Investigators},
  title = {A Prospective, Multicenter Evaluation of Safety and Diagnostic Outcomes With Robotic-Assisted Bronchoscopy},
  journal = {CHEST},
  year = {2025},
  volume = {168},
  number = {2},
  pages = {539--555},
  doi = {10.1016/j.chest.2025.04.022}
}
Kostenlos starten →