EUVIMEDObjevte EUVIMED
Open access · CC BY 4.0

Brachial blood flow and pressure responses are unrelated to the greater isometric handgrip tolerance of females compared to males

João L Marôco iD, Joseph Scangas, Megan Borges, Eric Bracken, Anton Pecha, Tracy Baynard, Bo Fernhall iD

Physiological Reports · 2026-04 · 14 (8)

DOI: 10.14814/phy2.70871 ↗

At a glance

Journal article in Physiological Reports, published online on 2026-04-15. Written by João L Marôco and 6 co-authors. Institution: Integrative Human Physiology Laboratory, Manning College of Nursing & Health Sciences, University of Massachusetts Boston, Boston, Massachusetts, USA. Major MEDLINE topics: Hand Strength, Brachial Artery, Blood Pressure, Isometric Contraction. 68 references. The full text is freely available (open access, CC BY 4.0).

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Isometric handgrip (IHG) training lowers blood pressure (BP), but sex differences in fatigability may be confounding. We hypothesized that the greater time‐to‐fatigue during IHG in females would relate to preserved brachial blood flow, with males exhibiting reductions in flow. Fifteen females and 14 males (18–32 years) completed a fatiguing IHG at 30% of maximum voluntary contraction (MVC). Brachial diameter and blood velocity were assessed with B‐mode and Doppler ultrasound, and BP via beat‐to‐beat finger photoplethysmography. Both sexes exhibited similar non‐significant increases in brachial flow during IHG (Δ HG‐rest = 30 mL min −1 , p = 0.200). Post‐exercise hyperemia was greater in males (Δ15 s post‐rest = 182 mL min −1 , 95% CI: 130–233 mL min −1 , p < 0.001) than in females (Δ15 s post‐rest = 89 mL min −1 , 95% CI: 39–138 mL min −1 , p < 0.001). Despite the mean arterial pressure response being greater in males (Δ = 30 mmHg, 95% CI: 24–37 mmHg, p < 0.001; vs. Δ = 17 mmHg, 95% CI: 10–23 mmHg, p < 0.001), conductance was similar between sexes during IHG ( p = 0.470). Time‐to‐fatigue was greater in females (243‐s vs. 181‐s, p = 0.021) and unrelated to flow. Controlling for MVC, brachial diameter, or arm circumference did not affect results. Brachial flow and pressor responses were unrelated to the greater fatigue resistance of young females. The greater post‐exercise hyperemia in males suggests a greater ischemic stimulus, independent of blood flow.

Subjects

MeSH terms (MEDLINE)

Hand StrengthBrachial ArteryBlood PressureIsometric ContractionHumansMaleFemaleYoung AdultAdultBlood Flow VelocityAdolescentRegional Blood FlowMuscle FatigueSex Characteristics

Author keywords

blood pressurebrachial blood flowfatigueisometric handgripsex differences

Authors and institutions

  • Integrative Human Physiology Laboratory, Manning College of Nursing & Health Sciences, University of Massachusetts Boston, Boston, Massachusetts, USA.

ORCID profiles: João L Marôco, Bo Fernhall

Cite

APA

Marôco, J. L., Scangas, J., Borges, M., Bracken, E., Pecha, A., Baynard, T., & Fernhall, B. (2026). Brachial blood flow and pressure responses are unrelated to the greater isometric handgrip tolerance of females compared to males. Physiological Reports, 14(8). https://doi.org/10.14814/phy2.70871

Vancouver

Marôco JL, Scangas J, Borges M, Bracken E, Pecha A, Baynard T, et al. Brachial blood flow and pressure responses are unrelated to the greater isometric handgrip tolerance of females compared to males. Physiological Reports. 2026;14(8). doi:10.14814/phy2.70871

BibTeX
@article{Marco2026,
  author = {Marôco, João L and Scangas, Joseph and Borges, Megan and Bracken, Eric and Pecha, Anton and Baynard, Tracy and Fernhall, Bo},
  title = {Brachial blood flow and pressure responses are unrelated to the greater isometric handgrip tolerance of females compared to males},
  journal = {Physiological Reports},
  year = {2026},
  volume = {14},
  number = {8},
  doi = {10.14814/phy2.70871}
}
Start for free →