Brachial blood flow and pressure responses are unrelated to the greater isometric handgrip tolerance of females compared to males
Physiological Reports · 2026-04 · 14 (8)
DOI: 10.14814/phy2.70871 ↗At a glance
Journal article in Physiological Reports, published online on 2026-04-15. Written by João L Marôco and 6 co-authors. Institution: Integrative Human Physiology Laboratory, Manning College of Nursing & Health Sciences, University of Massachusetts Boston, Boston, Massachusetts, USA. Major MEDLINE topics: Hand Strength, Brachial Artery, Blood Pressure, Isometric Contraction. 68 references. The full text is freely available (open access, CC BY 4.0).
Abstract (original language)
Isometric handgrip (IHG) training lowers blood pressure (BP), but sex differences in fatigability may be confounding. We hypothesized that the greater time‐to‐fatigue during IHG in females would relate to preserved brachial blood flow, with males exhibiting reductions in flow. Fifteen females and 14 males (18–32 years) completed a fatiguing IHG at 30% of maximum voluntary contraction (MVC). Brachial diameter and blood velocity were assessed with B‐mode and Doppler ultrasound, and BP via beat‐to‐beat finger photoplethysmography. Both sexes exhibited similar non‐significant increases in brachial flow during IHG (Δ HG‐rest = 30 mL min −1 , p = 0.200). Post‐exercise hyperemia was greater in males (Δ15 s post‐rest = 182 mL min −1 , 95% CI: 130–233 mL min −1 , p < 0.001) than in females (Δ15 s post‐rest = 89 mL min −1 , 95% CI: 39–138 mL min −1 , p < 0.001). Despite the mean arterial pressure response being greater in males (Δ = 30 mmHg, 95% CI: 24–37 mmHg, p < 0.001; vs. Δ = 17 mmHg, 95% CI: 10–23 mmHg, p < 0.001), conductance was similar between sexes during IHG ( p = 0.470). Time‐to‐fatigue was greater in females (243‐s vs. 181‐s, p = 0.021) and unrelated to flow. Controlling for MVC, brachial diameter, or arm circumference did not affect results. Brachial flow and pressor responses were unrelated to the greater fatigue resistance of young females. The greater post‐exercise hyperemia in males suggests a greater ischemic stimulus, independent of blood flow.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Integrative Human Physiology Laboratory, Manning College of Nursing & Health Sciences, University of Massachusetts Boston, Boston, Massachusetts, USA.
ORCID profiles: João L Marôco, Bo Fernhall
Cite
APA
Marôco, J. L., Scangas, J., Borges, M., Bracken, E., Pecha, A., Baynard, T., & Fernhall, B. (2026). Brachial blood flow and pressure responses are unrelated to the greater isometric handgrip tolerance of females compared to males. Physiological Reports, 14(8). https://doi.org/10.14814/phy2.70871
Vancouver
Marôco JL, Scangas J, Borges M, Bracken E, Pecha A, Baynard T, et al. Brachial blood flow and pressure responses are unrelated to the greater isometric handgrip tolerance of females compared to males. Physiological Reports. 2026;14(8). doi:10.14814/phy2.70871
BibTeX
@article{Marco2026,
author = {Marôco, João L and Scangas, Joseph and Borges, Megan and Bracken, Eric and Pecha, Anton and Baynard, Tracy and Fernhall, Bo},
title = {Brachial blood flow and pressure responses are unrelated to the greater isometric handgrip tolerance of females compared to males},
journal = {Physiological Reports},
year = {2026},
volume = {14},
number = {8},
doi = {10.14814/phy2.70871}
}
EUVIMED