Acute measurement of flow‐mediated dilation following passive heating in adults: The confounding role of altered shear stress and baseline vasodilation
Physiological Reports · 2026
DOI: 10.14814/phy2.70723 ↗At a glance
Journal article in Physiological Reports, 2026. Written by Campbell Menzies and 5 co-authors. Institution: Centre for Physical Activity, Sport & Exercise Sciences, Coventry University, Coventry, UK. Major MEDLINE topics: Vasodilation, Brachial Artery, Hot Temperature. 30 references. The full text is freely available (open access, CC BY 4.0).
Abstract (original language)
Changes in flow‐mediated dilation (FMD) following acute heating are not well understood, appear protocol‐specific, and may be better understood by additional measures of acute vasoactivity. This study investigated FMD responses before and after three different 30‐min hot‐water immersion conditions (40°C‐Shoulder, 42°C‐Waist, and 40°C‐Waist) in 22 adults. Brachial artery diameter was recorded at baseline (D base ), during the final 30 s of occlusion (D occ ), and at peak post‐occlusion (D peak ). Allometrically scaled FMD%, and changes in diameter during occlusion (OIV), and from end‐occlusion to peak diameter (FMD Docc ) were calculated. Pre‐occlusion shear rate was greater post‐immersion in 40‐Shoulder ( p < 0.001) and 42‐Waist (p < 0.001), but not 40‐Waist ( p = 0.13), with the largest increase observed in 40‐Shoulder. Alongside this, D base increased (Δ0.4 ± 0.2 mm, p < 0.001) and FMD% decreased (Δ−3.9 ± 3.8%, p = 0.04) following immersion in 40°C‐Shoulder only. Across all conditions, ΔFMD% was negatively associated with ΔD base ( r rm = −0.47, p = 0.001). OIV% was the only vasoactivity metric to statistically differentiate between all conditions post‐immersion (40°C‐Shoulder: −8.1 ± 4.9%. 42°C‐Waist: −3.0 ± 5.3%. 40°C‐Waist: 1.1 ± 4.1%. p < 0.001). Post‐heating FMD is confounded by heat‐induced increases in baseline diameter, even after allometric scaling, while OIV% may provide complementary insight into acute vasoactivity following passive heating.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Centre for Physical Activity, Sport & Exercise Sciences, Coventry University, Coventry, UK.
- School of Life Sciences, University of Nottingham, Nottingham, UK.
- College of Life Sciences, Faculty of Health, Education and Life Sciences, Birmingham City University, Birmingham, UK.
- Cardiff School of Sport & Health Sciences, Cardiff Metropolitan University, Cardiff, UK.
- Centre for Cardiovascular Research, Innovation and Development, Cardiff Metropolitan University, Cardiff, UK.
ORCID profiles: Campbell Menzies, Neil D Clarke, Charles J Steward, C Douglas Thake, Christopher J A Pugh, Tom Cullen
Cite
APA
Menzies, C., Clarke, N. D., Steward, C. J., Thake, C. D., Pugh, C. J. A., & Cullen, T. (2026). Acute measurement of flow‐mediated dilation following passive heating in adults: The confounding role of altered shear stress and baseline vasodilation. Physiological Reports. https://doi.org/10.14814/phy2.70723
Vancouver
Menzies C, Clarke ND, Steward CJ, Thake CD, Pugh CJA, Cullen T. Acute measurement of flow‐mediated dilation following passive heating in adults: The confounding role of altered shear stress and baseline vasodilation. Physiological Reports. 2026. doi:10.14814/phy2.70723
BibTeX
@article{Menzies2026,
author = {Menzies, Campbell and Clarke, Neil D and Steward, Charles J and Thake, C Douglas and Pugh, Christopher J A and Cullen, Tom},
title = {Acute measurement of flow‐mediated dilation following passive heating in adults: The confounding role of altered shear stress and baseline vasodilation},
journal = {Physiological Reports},
year = {2026},
doi = {10.14814/phy2.70723}
}
EUVIMED