Constant plasma volume and colloid osmotic pressure after infusion of albumin 20%: A secondary analysis
Physiological Reports · 2025
DOI: 10.14814/phy2.70623 ↗At a glance
Journal article in Physiological Reports, 2025. Written by Robert G Hahn. Institution: Research & Development, Karolinska Institute at Danderyds Hospital (KIDS), Stockholm, Sweden. Major MEDLINE topics: Plasma Volume, Osmotic Pressure, Albumins. Cited 1 times so far (Crossref); 27 references. The full text is freely available (open access, CC BY 4.0).
Abstract (original language)
Aberrant elimination patterns after intravenous infusion of albumin 20% may predispose to persistent vascular overload or hyper‐oncoticity. In the present report, the frequency of deviating elimination patterns was studied by visual examination followed by calculations of the volume and albumin kinetics over 5 hours in 86 volunteers and clinical patients who received 3 mL/kg albumin 20% over 30 min (mean, 231 mL). Constant and virtually unchanged plasma volume expansion (i.e., steady state) developed after 21% of all infusions and developed most often during surgery (64%) but rarely in volunteers (3%). The subsequent kinetic analysis associated such steady state with slow capillary filtration (−27% vs. all others, p < 0.01). Steady state or a gradual increase of the plasma oncotic pressure occurred in 28% and was characterized by fast turnover of fluid, which taken together resulted in a dehydrating effect. By contrast, steady state for plasma albumin was associated with a 48% lower capillary leakage rate constant for albumin ( p < 0.001) as compared to the other experiments. In conclusion, steady state for plasma volume and increasing colloid osmotic pressure after infusion of albumin 20% was more dependent on variations in fluid kinetics than on albumin kinetics.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Research & Development, Karolinska Institute at Danderyds Hospital (KIDS), Stockholm, Sweden.
ORCID profiles: Robert G Hahn
Cite
APA
Hahn, R. G. (2025). Constant plasma volume and colloid osmotic pressure after infusion of albumin 20%: A secondary analysis. Physiological Reports. https://doi.org/10.14814/phy2.70623
Vancouver
Hahn RG. Constant plasma volume and colloid osmotic pressure after infusion of albumin 20%: A secondary analysis. Physiological Reports. 2025. doi:10.14814/phy2.70623
BibTeX
@article{Hahn2025,
author = {Hahn, Robert G},
title = {Constant plasma volume and colloid osmotic pressure after infusion of albumin 20%: A secondary analysis},
journal = {Physiological Reports},
year = {2025},
doi = {10.14814/phy2.70623}
}