Fachartikel in der Zeitschrift Physiological Reports, 2025. Verfasst von Lars Øivind Høiseth und 4 weiteren Autor:innen. Beteiligte Einrichtung: Division of Emergencies and Critical Care, Oslo University Hospital, Oslo, Norway. Hauptthemen laut MEDLINE: Wearable Electronic Devices, Lower Body Negative Pressure, Electric Impedance, Fluid Shifts. Die Arbeit nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Research Council of Norway, Norges Forskningsråd.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Fluid extravasation is a prominent feature of several disease processes in acute and critical illness. Bioimpedance at frequencies representing extracellular and total resistance offers an opportunity to monitor fluid shifts. The aim of the present study was to explore if a novel wearable bioimpedance device could monitor fluid shifts during lower body negative pressure (LBNP). Eleven subjects underwent 40 min of LBNP at 30 mmHg. Bioimpedance was measured on the leg, upper back, and thoracic midaxillary line. Changes in resistance were compared using mixed linear regression. Further, hemoglobin and albumin concentrations were measured. Ten subjects completed the protocol. Compared to baseline, both extracellular and total resistance changed to the end of the LBNP exposure at all measurement sites. The mean extracellular resistance changed as follows: leg −6.6% (SD 3.1; p < 0.001), upper back 4.1% (SD 3.5; p < 0.001), and midaxillary line 6.3% (SD 2.8; p < 0.001). The wearable bioimpedance sensor detected the expected extracellular fluid shifts occurring with LBNP. Further clinical studies to explore if fluid extravasation in common pathologic conditions can be measured are warranted.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Wearable Electronic DevicesLower Body Negative PressureElectric ImpedanceFluid ShiftsHumansPilot ProjectsMaleFemaleAdultMonitoring, PhysiologicYoung Adult

Stichwörter der Autor:innen

diagnostic equipmentedemafluid shiftshypovolemialower body negative pressure

Autor:innen und Institutionen

  • Division of Emergencies and Critical Care, Oslo University Hospital, Oslo, Norway.
  • Institute of Clinical Medicine, University of Oslo, Oslo, Norway.
  • Mode Sensors AS, Trondheim, Norway.

ORCID-Profile: Lars Øivind Høiseth, Frida Bremnes, Sigve Nyvik Aas

Förderung

  • Research Council of Norway
  • Norges Forskningsråd

Zitieren

APA

Høiseth, L. Ø., Bremnes, F., Aas, S. N., Thorud, A., & Noddeland, H. (2025). Wearable and noninvasive monitoring of fluid shifts: A pilot study assessing a novel bioimpedance sensor during lower body negative pressure. Physiological Reports. https://doi.org/10.14814/phy2.70603

Vancouver

Høiseth LØ, Bremnes F, Aas SN, Thorud A, Noddeland H. Wearable and noninvasive monitoring of fluid shifts: A pilot study assessing a novel bioimpedance sensor during lower body negative pressure. Physiological Reports. 2025. doi:10.14814/phy2.70603

BibTeX
@article{Hiseth2025,
  author = {Høiseth, Lars Øivind and Bremnes, Frida and Aas, Sigve Nyvik and Thorud, Anne and Noddeland, Harald},
  title = {Wearable and noninvasive monitoring of fluid shifts: A pilot study assessing a novel bioimpedance sensor during lower body negative pressure},
  journal = {Physiological Reports},
  year = {2025},
  doi = {10.14814/phy2.70603}
}
Kostenlos starten →