Wireless arm-worn bioimpedance sensor for continuous assessment of whole-body hydration
Proceedings of the National Academy of Sciences · 2025
DOI: 10.1073/pnas.2504278122 ↗Kurz gefasst
Fachartikel in der Zeitschrift Proceedings of the National Academy of Sciences, 2025. Verfasst von Matija Jankovic und 12 weiteren Autor:innen. Beteiligte Einrichtung: Chandra Family Department of Electrical and Computer Engineering, The University of Texas at Austin, Austin, TX 78712. Hauptthemen laut MEDLINE: Electric Impedance, Arm, Wearable Electronic Devices, Dehydration. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: DOD | USN | Office of Naval Research (ONR), National Science Foundation (NSF).
Abstract (Originalsprache)
Assessment of whole-body hydration (WBH) is crucial for health management and disease diagnosis. Traditional methods are invasive or require bulky equipment, making them impractical for mobile, continuous sensing. We present a wearable bioimpedance sensor with strategic electrode placement across the arm for noninvasive, continuous, and mobile WBH monitoring. Although whole-body bioimpedance is a proven method for indicating WBH, the effectiveness of local bioimpedance measurement has been unclear. Our finite element analysis demonstrated that with an optimized cross-arm sensing configuration, a strong linear relationship exists between arm bioimpedance and muscle electrical resistivity, confirming the utility of arm bioimpedance for assessing WBH given the well-established relationship between muscle electrical resistivity and body water. Our IRB-approved diuretic-induced dehydration study demonstrated a strong linear correlation between the increase of arm bioimpedance and the decrease in body weight due to water loss, with a Pearson correlation coefficient of 0.956 ± 0.033 among eight participants. Arm and whole-body demonstrated strong alignment, suggesting that arm bioimpedance measurements can reflect not only changes in WBH but also potentially absolute WBH status when compared against established population reference data. In a 24-h free-living experiment, the wireless, dry electrode-based, arm-conformable bioimpedance sensor continuously tracked dehydration and rehydration despite motions associated with daily activities. These results suggest that properly measured arm bioimpedance can serve as a surrogate for WBH, offering a reliable and accessible solution. The potential uses of this wearable technology range from improving personal wellness to enhancing professional sports and occupational safety.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Chandra Family Department of Electrical and Computer Engineering, The University of Texas at Austin, Austin, TX 78712.
- Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX 78712.
- Department of Kinesiology and Health Education, The University of Texas at Austin, Austin, TX 78712.
- Department of Mechanical Engineering, The University of Texas at Austin, Austin, TX 78712.
- Stretch Med Inc, Austin, TX 78750.
- Department of Aerospace Engineering and Engineering Mechanics, The University of Texas at Austin, Austin, TX 78712.
ORCID-Profile: Matija Jankovic, Seungmin Kang, Sarnab Bhattacharya, Jieting Wang, Tianda Huang, Nanshu Lu
Förderung
- DOD | USN | Office of Naval Research (ONR)
- National Science Foundation (NSF)
Zitieren
APA
Jankovic, M., Kang, S., Bhattacharya, S., Kashanchi, J., Wang, J., Deoli, K., Huang, T., Johnson, A., Ambani, K., Kim, S., Wang, P., Coyle, E., & Lu, N. (2025). Wireless arm-worn bioimpedance sensor for continuous assessment of whole-body hydration. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.2504278122
Vancouver
Jankovic M, Kang S, Bhattacharya S, Kashanchi J, Wang J, Deoli K, et al. Wireless arm-worn bioimpedance sensor for continuous assessment of whole-body hydration. Proceedings of the National Academy of Sciences. 2025. doi:10.1073/pnas.2504278122
BibTeX
@article{Jankovic2025,
author = {Jankovic, Matija and Kang, Seungmin and Bhattacharya, Sarnab and Kashanchi, Jordon and Wang, Jieting and Deoli, Kanika and Huang, Tianda and Johnson, Alex and Ambani, Karina and Kim, Sangjun and Wang, Pulin and Coyle, Edward and Lu, Nanshu},
title = {Wireless arm-worn bioimpedance sensor for continuous assessment of whole-body hydration},
journal = {Proceedings of the National Academy of Sciences},
year = {2025},
doi = {10.1073/pnas.2504278122}
}
EUVIMED