Challenges in zero‐flow blood pressure as a measure of mean circulatory filling pressure: Experimental and computational perspectives
Physiological Reports · 2025
DOI: 10.14814/phy2.70599 ↗At a glance
Journal article in Physiological Reports, 2025. Written by L M van Loon and 5 co-authors. Institution: Cardiovascular and Respiratory Physiology, Technical Medical Centre, University of Twente, Enschede, The Netherlands. Major MEDLINE topics: Blood Pressure, Models, Cardiovascular, Heart Arrest, Hemodynamics. 30 references. The full text is freely available (open access, CC BY 4.0). Funded by: ZonMw (Netherlands Organisation for Health Research and Development).
Abstract (original language)
Mean circulatory filling pressure (MCFP) is a foundational hemodynamic concept, representing the average circulatory pressure in a no‐flow state and used to assess volume status and venous return. However, its measurement and clinical relevance remain debated. In this study, zero‐flow pressures were recorded in 14 healthy pigs following cardiac arrest. Measurements were taken for 10 min in the abdominal aorta and right atrium under two conditions: cardiac arrest induced by pentobarbital overdose or by ventricular fibrillation (VF), with half of the VF animals rendered hypovolemic. A validated computational model of cardiovascular physiology was used to simulate these scenarios. Pentobarbital caused a rapid pressure equilibration, with mean arterial pressure (MAP) falling from 47 ± 3.7 to 16 ± 2.5 mm Hg. In contrast, VF produced a dynamic pressure response: MAP dropped from 53 ± 4.7 to 17 ± 2.2 mm Hg while central venous pressure rose, producing a persistent retrograde pressure gradient (5 ± 2.1 mm Hg). In silico simulations closely matched these dynamics (normalized RMSE
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Cardiovascular and Respiratory Physiology, Technical Medical Centre, University of Twente, Enschede, The Netherlands.
- Department of Intensive Care Medicine, Radboud University Medical Center, Nijmegen, The Netherlands.
- Intensive Care Center, University Medical Center Utrecht, Utrecht, The Netherlands.
- Department of Cardiology, Radboud University Medical Center, Nijmegen, The Netherlands.
- Radboud Center for Infectious Diseases, Nijmegen, The Netherlands.
ORCID profiles: L M van Loon
Funding
- ZonMw (Netherlands Organisation for Health Research and Development)
Cite
APA
van Loon, L. M., Mulder, M. P., van Dort, D., van der Hoeven, J. G., Donker, D. W., & Lemson, J. (2025). Challenges in zero‐flow blood pressure as a measure of mean circulatory filling pressure: Experimental and computational perspectives. Physiological Reports. https://doi.org/10.14814/phy2.70599
Vancouver
van Loon LM, Mulder MP, van Dort D, van der Hoeven JG, Donker DW, Lemson J. Challenges in zero‐flow blood pressure as a measure of mean circulatory filling pressure: Experimental and computational perspectives. Physiological Reports. 2025. doi:10.14814/phy2.70599
BibTeX
@article{vanLoon2025,
author = {van Loon, L M and Mulder, M P and van Dort, D and van der Hoeven, J G and Donker, D W and Lemson, J},
title = {Challenges in zero‐flow blood pressure as a measure of mean circulatory filling pressure: Experimental and computational perspectives},
journal = {Physiological Reports},
year = {2025},
doi = {10.14814/phy2.70599}
}
EUVIMED