EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

Untangling discrepancies between cerebrovascular autoregulation correlation coefficients: An exploration of filters, coherence and power

Stefan Yu Bögli iD, Ihsane Olakorede, Erta Beqiri, Giada Cucciolini, Virginia Motroni, Claudia Ann Smith, Marina Sandra Cherchi, Ronan O'Leary, Peter Smielewski

Physiological Reports · 2025-04 · 13 (8)

DOI: 10.14814/phy2.70332 ↗

At a glance

Journal article in Physiological Reports, published online on 2025-04-17. Written by Stefan Yu Bögli and 8 co-authors. Institution: Brain Physics Laboratory, Division of Neurosurgery, Department of Clinical Neurosciences, University of Cambridge, Cambridge, UK. Major MEDLINE topics: Cerebrovascular Circulation, Homeostasis, Brain Injuries, Traumatic. Cited 9 times so far (Crossref); 32 references. The full text is freely available (open access, CC BY 4.0). Funded by: Swiss National Science Foundation, Cambridge Trust CIS Scholarship, Medical Research Council and Gates Cambridge Scholarship.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

A bstract Cerebrovascular autoregulation (CAR) maintains stable cerebral perfusion by adjusting arteriole diameters in response to slow pressure fluctuations. Various CAR correlation coefficients—PRx (based on intracranial pressure—ICP), Mx (based on transcranial doppler—TCD), and COx/THx (based on near‐infrared spectroscopy—NIRS)—are used interchangeably despite fundamental differences. 566 hours of ICP, NIRS, and TCD data from 38 traumatic brain injury (TBI) patients were assessed. The intercorrelation between CAR correlation coefficients was compared in relation to: (1) The impact of different filtering methods (to minimize noise); (2) The impact of slow wave power (i.e., magnitude of incoming trigger); (3) The impact of coherence (i.e., to what extent can the power of slow waves explain the change in power within the cerebral biosignal). Only coherence stratification consistently increased the metric intercorrelation to PRx (high vs. low) when evaluating Mx (0.43 vs. 0.08, p < 0.01) and THx (0.36 vs. 0.05, p < 0.01). Additionally, high coherence and ABP power were associated with fewer correlation coefficients around 0. Coherence increases the intercorrelation between the different CAR metrics. These sections might be regarded as more reliable, since they are derived from different biosignals that are all affected by CAR through different mechanisms.

Subjects

MeSH terms (MEDLINE)

Cerebrovascular CirculationHomeostasisBrain Injuries, TraumaticHumansMaleAdultFemaleUltrasonography, Doppler, TranscranialMiddle AgedSpectroscopy, Near-InfraredIntracranial PressureYoung Adult

Author keywords

cerebrovascular autoregulationintensive caremultimodality monitoringtraumatic brain injury

Authors and institutions

  • Brain Physics Laboratory, Division of Neurosurgery, Department of Clinical Neurosciences, University of Cambridge, Cambridge, UK.
  • Department of Neurology and Neurocritical Care Unit, Clinical Neuroscience Center, University Hospital Zurich, University of Zurich, Zurich, Switzerland.
  • Department of Surgical, Medical, Molecular Pathology and Critical Care Medicine, University of Pisa, Pisa, Italy.
  • Departmental Structure of Neuroanesthesia and Critical Care, Azienda Ospedaliero-Universitaria Pisana, Pisa, Italy.
  • Department of Critical Care, Marques de Valdecilla University Hospital, and Biomedical Research Institute (IDIVAL), Santander, Cantabria, Spain.
  • Neurosciences and Trauma Critical Care Unit, Addenbrooke's Hospital, Cambridge University Hospitals, Cambridge, UK.

ORCID profiles: Stefan Yu Bögli

Funding

  • Swiss National Science Foundation
  • Cambridge Trust CIS Scholarship
  • Medical Research Council and Gates Cambridge Scholarship
  • Patrick and Margaret Flanagan Skye Cambridge Trust Scholarship
  • Cantabrian Health Service
  • Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung

Cite

APA

Bögli, S. Y., Olakorede, I., Beqiri, E., Cucciolini, G., Motroni, V., Smith, C. A., Cherchi, M. S., O'Leary, R., & Smielewski, P. (2025). Untangling discrepancies between cerebrovascular autoregulation correlation coefficients: An exploration of filters, coherence and power. Physiological Reports, 13(8). https://doi.org/10.14814/phy2.70332

Vancouver

Bögli SY, Olakorede I, Beqiri E, Cucciolini G, Motroni V, Smith CA, et al. Untangling discrepancies between cerebrovascular autoregulation correlation coefficients: An exploration of filters, coherence and power. Physiological Reports. 2025;13(8). doi:10.14814/phy2.70332

BibTeX
@article{Bgli2025,
  author = {Bögli, Stefan Yu and Olakorede, Ihsane and Beqiri, Erta and Cucciolini, Giada and Motroni, Virginia and Smith, Claudia Ann and Cherchi, Marina Sandra and O'Leary, Ronan and Smielewski, Peter},
  title = {Untangling discrepancies between cerebrovascular autoregulation correlation coefficients: An exploration of filters, coherence and power},
  journal = {Physiological Reports},
  year = {2025},
  volume = {13},
  number = {8},
  doi = {10.14814/phy2.70332}
}