Feasibility of replacing 99m Tc ‐ DTPA GFR measurements with eGFR from cystatin C in individuals with spinal cord injuries

Tatiana Kristensen, Peter S Oturai, Bryan T Haddock, Fin Biering-Sørensen, Christina Kruuse, Ulrik B Andersen iD

Physiological Reports · 2025-05 · 13 (9)

DOI: 10.14814/phy2.70315 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physiological Reports, online erschienen am 12.05.2025. Verfasst von Tatiana Kristensen und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Physiology and Nuclear Medicine, Copenhagen University Hospital - Rigshospitalet; Glostrup, Copenhagen, Denmark. Hauptthemen laut MEDLINE: Cystatin C, Glomerular Filtration Rate, Spinal Cord Injuries, Technetium Tc 99m Pentetate. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In individuals with spinal cord injury (SCI) and neurogenic bladder dysfunction, guidelines recommend regular monitoring of kidney function by measuring the glomerular filtration rate using an externally administered filtration markers such as 99mTc‐DTPA, since creatinine‐based eGFR models are inaccurate due to lower muscle mass in these individuals. To examine the feasibility of substituting GFR measurements with eGFR based on s‐cystatin C, simultaneous 99mTc‐DTPA clearance (mGFR) and cystatin C‐based clearance (eGFRcys) measures were evaluated in 248 individuals with SCI. In a subgroup of 26 participants, the test–retest variability of eGFRcys was assessed. Finally, long‐term (1–3 years) repeatability of simultaneously measured mGFR and eGFRcys was evaluated in 40 individuals. We could demonstrate a very good correlation between mGFR and eGFRcys, with an intraclass correlation (ICC) of 0.92, a very good test–retest variation of eGFRcys (ICC: 0.98) and a very good long‐term repeatability of eGFRcys and mGFR (ICC 0.92 and 0.94, respectively). We conclude that in individuals with SCI, eGFR calculated from a single sample of cystatin C can replace measurements of GFR using an externally administered substance. Using a fixed normal limit rather than an age‐corrected normal material for p‐cystatin C or eGFRCYS will misclassify many individuals as having chronic kidney disease.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cystatin CGlomerular Filtration RateSpinal Cord InjuriesTechnetium Tc 99m PentetateHumansMaleFemaleMiddle AgedAdultFeasibility StudiesAgedRadiopharmaceuticalsReproducibility of ResultsUrinary Bladder, NeurogenicKidney Function TestsYoung AdultBiomarkers

Stichwörter der Autor:innen

DTPA‐clearanceGFRcystatin CeGFRkidney dysfunctionspinal cord injury

Substanzen

Cystatin CTechnetium Tc 99m PentetateRadiopharmaceuticalsBiomarkers

Autor:innen und Institutionen

  • Department of Clinical Physiology and Nuclear Medicine, Copenhagen University Hospital - Rigshospitalet; Glostrup, Copenhagen, Denmark.
  • Department of Brain and Spinal Cord Injury, Neuroscience Center, Copenhagen University Hospital - Rigshospitalet; Glostrup, Copenhagen, Denmark.
  • Institute of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark.

ORCID-Profile: Ulrik B Andersen

Zitieren

APA

Kristensen, T., Oturai, P. S., Haddock, B. T., Biering-Sørensen, F., Kruuse, C., & Andersen, U. B. (2025). Feasibility of replacing 99m Tc ‐ DTPA GFR measurements with eGFR from cystatin C in individuals with spinal cord injuries. Physiological Reports, 13(9). https://doi.org/10.14814/phy2.70315

Vancouver

Kristensen T, Oturai PS, Haddock BT, Biering-Sørensen F, Kruuse C, Andersen UB. Feasibility of replacing 99m Tc ‐ DTPA GFR measurements with eGFR from cystatin C in individuals with spinal cord injuries. Physiological Reports. 2025;13(9). doi:10.14814/phy2.70315

BibTeX
@article{Kristensen2025,
  author = {Kristensen, Tatiana and Oturai, Peter S and Haddock, Bryan T and Biering-Sørensen, Fin and Kruuse, Christina and Andersen, Ulrik B},
  title = {Feasibility of replacing 99m Tc ‐ DTPA GFR measurements with eGFR from cystatin C in individuals with spinal cord injuries},
  journal = {Physiological Reports},
  year = {2025},
  volume = {13},
  number = {9},
  doi = {10.14814/phy2.70315}
}
Kostenlos starten →