Applicability of Creatinine‐ and Cystatin C‐Based Estimated Glomerular Filtration Rate Equations in Patients With Neurogenic Lower Urinary Tract Dysfunction
Neurourology and Urodynamics · 2026
DOI: 10.1002/nau.70147 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Neurourology and Urodynamics, 2026. Verfasst von Yuanyuan Wei und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Rehabilitation Medicine, Capital Medical University, Beijing, China. Hauptthemen laut MEDLINE: Creatinine, Cystatin C, Glomerular Filtration Rate, Kidney. Die Arbeit nennt 30 Literaturangaben. Gefördert von: This study was supported by the foundation of Key Technologies Research and Development Program (2023YFC3605300), and the foundation of China Rehabilitation Re….
Abstract (Originalsprache)
Objectives
To assess the applicability of Chronic Kidney Disease Epidemiology Collaboration (CKD‐EPI) equations and Chinese eGFR Investigation Collaboration (C‐eGFR) equations in estimating glomerular filtration rate (GFR) in patients with neurogenic lower urinary tract dysfunction (NLUTD). These equations are based on serum creatinine, cystatin C, or combined creatinine and cystatin C.
Methods
This prospective study enrolled 142 adult patients with NLUTD. GFR was measured using the dual plasma ⁹⁹mTc‐DTPA plasma clearance method. We compared the bias, precision, accuracy and correct classification percentage of six estimated glomerular filtration rate (eGFR) equations, including CKD‐EPI creatinine equation (CKD‐EPIcr), C‐eGFR creatinine equation (C‐eGFRcr), CKD‐EPI creatinine‐cystatin C equation (CKD‐EPIcr‐cys), C‐eGFR creatinine‐cystatin C equation (C‐eGFRcr‐cys), CKD‐EPI cystatin C equation (CKD‐EPIcys), and C‐eGFR cystatin C equation (C‐eGFRcys).
Results
The median (interquartile range [IQR]) of measured GFR (mGFR) was 60.54 (34.66–86.28) mL/min/1.73 m². Both CKD‐EPIcr and C‐eGFRcr significantly overestimated GFR (median differences of 17.20 and 13.60 mL/min/1.73 m², respectively; both p < 0.01), and P 30 values (percentage of estimated GFR within 30% of mGFR) were 51% and 57%, respectively. CKD‐EPIcr‐cys demonstrated superior performance than C‐eGFRcr‐cys (median difference: 2.07 vs 9.13 mL/min/1.73 m²; both p < 0.01; P 30 : 84% vs 69%). CKD‐EPIcys achieved the highest P 30 (88%), while C‐eGFRcys showed minimal bias (median difference: 0.42 mL/min/1.73 m²; p = 0.69). CKD‐EPIcr‐cys, CKD‐EPIcys, and C‐eGFRcys all achieved acceptable P 30 values and correct classification percentage. CKD‐EPIcr‐cys performed optimally at mGFR ≥ 60 mL/min/1.73 m², whereas CKD‐EPIcys was superior at mGFR < 60 mL/min/1.73 m².
Conclusion
Creatinine‐based equations systematically overestimate GFR in NLUTD patients and should be used with caution. In contrast, cystatin C‐based equations—whether used alone (e.g., CKD‐EPIcys, C‐eGFRcys) or combined with creatinine (e.g., CKD‐EPIcr‐cys)—demonstrate superior accuracy and should be preferred for GFR estimation in NLUTD patients. Clinical Trial Registration The Chinese clinical trial registration number is ChiCTR2100054934.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Rehabilitation Medicine, Capital Medical University, Beijing, China.
- Department of Nephrology, China Rehabilitation Research Center, Beijing Boai Hospital, Beijing, China.
- Department of Laboratory, China Rehabilitation Research Center, Beijing Boai Hospital, Beijing, China.
- Department of Urology, China Rehabilitation Research Center, Beijing Boai Hospital, Beijing, China.
ORCID-Profile: Yuanyuan Wei, Shuang Li, Dong An, Liang Chen, Zhizhong Liu, Yingchun Ma, Limin Liao
Förderung
- This study was supported by the foundation of Key Technologies Research and Development Program (2023YFC3605300), and the foundation of China Rehabilitation Re…
Zitieren
APA
Wei, Y., Li, S., An, D., Chen, L., Liu, Z., Ma, Y., & Liao, L. (2026). Applicability of Creatinine‐ and Cystatin C‐Based Estimated Glomerular Filtration Rate Equations in Patients With Neurogenic Lower Urinary Tract Dysfunction. Neurourology and Urodynamics. https://doi.org/10.1002/nau.70147
Vancouver
Wei Y, Li S, An D, Chen L, Liu Z, Ma Y, et al. Applicability of Creatinine‐ and Cystatin C‐Based Estimated Glomerular Filtration Rate Equations in Patients With Neurogenic Lower Urinary Tract Dysfunction. Neurourology and Urodynamics. 2026. doi:10.1002/nau.70147
BibTeX
@article{Wei2026,
author = {Wei, Yuanyuan and Li, Shuang and An, Dong and Chen, Liang and Liu, Zhizhong and Ma, Yingchun and Liao, Limin},
title = {Applicability of Creatinine‐ and Cystatin C‐Based Estimated Glomerular Filtration Rate Equations in Patients With Neurogenic Lower Urinary Tract Dysfunction},
journal = {Neurourology and Urodynamics},
year = {2026},
doi = {10.1002/nau.70147}
}
EUVIMED