Ventilatory efficiency in cardiac amyloidosis—A systematic review and meta‐analysis
Physiological Reports · 2025-05 · 13 (9)
DOI: 10.14814/phy2.70308 ↗At a glance
Metaanalyse in Physiological Reports, published online on 2025-05-01. Written by Robin Willixhofer and 5 co-authors. Institution: Centro Cardiologico Monzino, IRCCS, Milan, Italy. Major MEDLINE topics: Amyloidosis, Cardiomyopathies, Pulmonary Ventilation. Cited 6 times so far (Crossref); 44 references. The full text is freely available (open access, CC BY 4.0). Funded by: Fondazione IEO-MONZINO, Italian Ministry of Health, Ministero della Salute.
Abstract (original language)
In cardiac amyloidosis (CA) cardiopulmonary exercise testing (CPET) is underexplored. This study evaluated exercise limitations in CA using CPET, focusing on the ventilation‐to‐carbon dioxide production (VE/VCO 2 ) slope and peak oxygen uptake (VO 2 ). Seventeen studies involving 1505 patients were analyzed and systematically reviewed according to PRISMA reporting guidelines. Subgroup analyses assessed differences by diagnosis (ATTR vs. AL), CPET modality, and age. The cohort included 12% with AL, 80% with ATTR (23% hereditary [ATTRv], 70% wild‐type [ATTRwt], 7% unspecified), and 8% unidentified subtypes. VE/VCO 2 slope was elevated across ATTR subgroups: 38.4 (95% CI: 36.9–40.0, I 2 = 57%) in ATTRwt and 37.9 (95% CI: 35.1–40.7, I 2 = 70%) in ATTRv. ATTR patients were older than AL patients by 9.0 years (95% CI: 0.4–17.6, I 2 = 88%) and had a higher VE/VCO 2 slope: 2.5 (95% CI: 0.2–4.8, I 2 = 0%). CPET modality influenced peak VO 2 , which was lowest for treadmill exercise (13.7, 95% CI: 12.7–14.8, I 2 = 0%, mL/min/kg) compared to upright cycle ergometry (14.7, 95% CI: 14.3–15.1, I 2 = 33%) and semi‐recumbent cycle ergometry (14.5, 95% CI: 14.1–14.9, I 2 = 28%). A high VE/VCO 2 slope characterizes both ATTRwt and ATTRv, while AL patients are younger with lower VE/VCO 2 slope levels. Peak VO 2 in ATTR patients may depend on exercise modality.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Centro Cardiologico Monzino, IRCCS, Milan, Italy.
- Department of Clinical Sciences and Community Health, University of Milan, Milan, Italy.
- Cento Cardiologico Monzino, L'unita di Biostatistica, IRCCS, Milan, Italy.
ORCID profiles: Piergiuseppe Agostoni
Funding
- Fondazione IEO-MONZINO
- Italian Ministry of Health
- Ministero della Salute
Cite
APA
Willixhofer, R., Salvioni, E., Capra, N., Contini, M., Campodonico, J., & Agostoni, P. (2025). Ventilatory efficiency in cardiac amyloidosis—A systematic review and meta‐analysis. Physiological Reports, 13(9). https://doi.org/10.14814/phy2.70308
Vancouver
Willixhofer R, Salvioni E, Capra N, Contini M, Campodonico J, Agostoni P. Ventilatory efficiency in cardiac amyloidosis—A systematic review and meta‐analysis. Physiological Reports. 2025;13(9). doi:10.14814/phy2.70308
BibTeX
@article{Willixhofer2025,
author = {Willixhofer, Robin and Salvioni, Elisabetta and Capra, Nicolò and Contini, Mauro and Campodonico, Jeness and Agostoni, Piergiuseppe},
title = {Ventilatory efficiency in cardiac amyloidosis—A systematic review and meta‐analysis},
journal = {Physiological Reports},
year = {2025},
volume = {13},
number = {9},
doi = {10.14814/phy2.70308}
}
EUVIMED