EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

Measuring lung mechanics in patients with COPD using the handheld portable rapid expiratory occlusion monitor ( REOM ): A cross‐sectional study

Felix-Antoine Coutu, Dany Malaeb, Olivia C Iorio, Seyedfakhreddin Nabavi, Tom McFarland, Lennart K A Lundblad, Ron J Dandurand, Stewart B Gottfried, Bryan A Ross iD

Physiological Reports · 2025

DOI: 10.14814/phy2.70307 ↗

At a glance

Journal article in Physiological Reports, 2025. Written by Felix-Antoine Coutu and 8 co-authors. Institution: Respiratory Epidemiology and Clinical Research Unit, Centre for Outcomes Research and Evaluation, Research Institute of the McGill University Health …. Major MEDLINE topics: Pulmonary Disease, Chronic Obstructive, Respiratory Mechanics, Lung. Cited 2 times so far (Crossref); 59 references. The full text is freely available (open access, CC BY 4.0). Funded by: Innovations & Partnerships (McGill University & Thorasys Inc.), MUHC Contract Academic Staff (MUHC CAS) Award.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

While conventional spirometry is associated with strenuous “forced” maximal respiratory maneuvers and infection control implications, oscillometry is not associated with these issues. However, portability, convenience of use, and interpretation remain common limitations to both techniques. This study tested the concordance and agreement between resistance measurements obtained from the handheld portable REOM device (R eo‐f , R eo‐s ) with those from conventional oscillometry (R 19 , R 5 ) in PFT‐confirmed “mild” (GOLD 1) and “very severe” (GOLD 4) COPD. Unadjusted and adjusted concordance (Spearman correlation) and agreement (Bland–Altman tests) served as co‐primary outcomes. Discrimination between GOLD 1 and 4 COPD (Wilcoxon rank sum test, Support Vector Machine (SVM) classifier) and patient user experience (System Utility Scale (SUS), Participant Satisfaction Survey (PSS)) served as secondary outcomes. In 17 participants (GOLD 1 n = 9, GOLD 4 n = 8), adjusted R 5 ‐R eo‐s (0.95 [0.81, 0.98]) and R 19 ‐R eo‐f (0.93 [0.79, 0.99]) correlations were very strong, as was agreement (mean differences: −0.07, 0.08, respectively). Statistically significant between‐group differences were observed for all four resistance parameters. R eo‐s in particular exhibited perfect discrimination between GOLD 1 and 4 disease, with some minor misclassification by R eo‐f , R 5 ( n = 1 each) and R 19 ( n = 4). User experience scores were excellent. These results support the capacity for REOM as a novel, complementary diagnostic device in COPD.

Subjects

MeSH terms (MEDLINE)

Pulmonary Disease, Chronic ObstructiveRespiratory MechanicsLungHumansMaleFemaleMiddle AgedCross-Sectional StudiesAgedSpirometryOscillometry

Author keywords

chronic obstructive pulmonary disease (COPD)handheld portable deviceinterrupter techniqueoscillometryrespiratory resistance

Authors and institutions

  • Respiratory Epidemiology and Clinical Research Unit, Centre for Outcomes Research and Evaluation, Research Institute of the McGill University Health Centre, Montreal, Quebec, Canada.
  • Department of Medicine, McGill University, Montreal, Quebec, Canada.
  • Meakins-Christie Laboratories, McGill University, Montreal, Quebec, Canada.
  • THORASYS Thoracic Medical Systems Inc., Montreal, Quebec, Canada.
  • Montreal Chest Institute, McGill University Health Centre, Montreal, Quebec, Canada.
  • Lakeshore General Hospital, Pointe-Claire, Quebec, Canada.

ORCID profiles: Bryan A Ross

Funding

  • Innovations & Partnerships (McGill University & Thorasys Inc.)
  • MUHC Contract Academic Staff (MUHC CAS) Award

Cite

APA

Coutu, F. A., Malaeb, D., Iorio, O. C., Nabavi, S., McFarland, T., Lundblad, L. K. A., Dandurand, R. J., Gottfried, S. B., & Ross, B. A. (2025). Measuring lung mechanics in patients with COPD using the handheld portable rapid expiratory occlusion monitor ( REOM ): A cross‐sectional study. Physiological Reports. https://doi.org/10.14814/phy2.70307

Vancouver

Coutu FA, Malaeb D, Iorio OC, Nabavi S, McFarland T, Lundblad LKA, et al. Measuring lung mechanics in patients with COPD using the handheld portable rapid expiratory occlusion monitor ( REOM ): A cross‐sectional study. Physiological Reports. 2025. doi:10.14814/phy2.70307

BibTeX
@article{Coutu2025,
  author = {Coutu, Felix-Antoine and Malaeb, Dany and Iorio, Olivia C and Nabavi, Seyedfakhreddin and McFarland, Tom and Lundblad, Lennart K A and Dandurand, Ron J and Gottfried, Stewart B and Ross, Bryan A},
  title = {Measuring lung mechanics in patients with COPD using the handheld portable rapid expiratory occlusion monitor ( REOM ): A cross‐sectional study},
  journal = {Physiological Reports},
  year = {2025},
  doi = {10.14814/phy2.70307}
}
Start for free →