EUVIMEDSkopri EUVIMED
Open access · CC BY 4.0

Shape factor versus truncated cone‐based quantification of quadriceps and hamstring muscle volumes—A choice between accuracy and precision

Daniel P Fitze iD, Nicola Mair-Noack, Dominik Brun, Daniel Nanz iD, Jess G Snedeker iD, Jörg Spörri iD

Physiological Reports · 2025

DOI: 10.14814/phy2.70263 ↗

At a glance

Journal article in Physiological Reports, 2025. Written by Daniel P Fitze and 5 co-authors. Institution: Sports Medical Research Group, Department of Orthopaedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland. Major MEDLINE topics: Quadriceps Muscle, Hamstring Muscles, Magnetic Resonance Imaging. Cited 1 times so far (Crossref); 36 references. The full text is freely available (open access, CC BY 4.0). Funded by: Balgrist Foundation.

AstrattSubjectsDettalji biblijografiċiCiteRelated studies

Abstract (original language)

This study aimed to determine the average location of maximal anatomical cross‐sectional area of the quadriceps and hamstrings and to investigate the agreement of different muscle volume estimation methods. Magnetic resonance imaging datasets were acquired from 39 soccer players. Muscle volumes were calculated using slice‐by‐slice segmentation and compared with the shape factor and truncated cone‐based estimates. Descriptive data were expressed as means ± standard deviations, and Bland–Altman plots were used for agreement analyses. The average location of maximal anatomical cross‐sectional area was at 61 ± 10%, 64 ± 10%, 29 ± 3%, and 56 ± 6% for the vastus lateralis, rectus femoris, vastus medialis, and vastus intermedius, respectively. For the hamstrings, the maximal anatomical cross‐sectional area was at 45 ± 3%, 48 ± 9%, 58 ± 7%, and 38 ± 8% for the biceps femoris short head, biceps femoris long head, semitendinosus, and semimembranosus, respectively. Relative biases ranged from 2% to 9% for the shape factor and from 6% to 14% for the truncated cone method. The ranges of agreement were −15% to 29% and −1% to 19%, respectively. The shape factor method showed better accuracy, while the truncated cone method displayed better precision.

Subjects

MeSH terms (MEDLINE)

Quadriceps MuscleHamstring MusclesMagnetic Resonance ImagingHumansMaleYoung AdultAdultOrgan SizeSoccer

Author keywords

hamstring musclesmagnetic resonance imagingmuscle volumequadriceps musclessegmentation

Authors and institutions

  • Sports Medical Research Group, Department of Orthopaedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland.
  • University Center for Prevention and Sports Medicine, Department of Orthopaedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland.
  • Swiss Center for Musculoskeletal Imaging, Balgrist Campus AG, Zurich, Switzerland.
  • Medical Faculty, University of Zurich, Zurich, Switzerland.
  • Biomechanics Laboratory, Department of Orthopaedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland.
  • Institute for Biomechanics, ETH Zurich, Zurich, Switzerland.

ORCID profiles: Daniel P Fitze, Daniel Nanz, Jess G Snedeker, Jörg Spörri

Funding

  • Balgrist Foundation

Cite

APA

Fitze, D. P., Mair-Noack, N., Brun, D., Nanz, D., Snedeker, J. G., & Spörri, J. (2025). Shape factor versus truncated cone‐based quantification of quadriceps and hamstring muscle volumes—A choice between accuracy and precision. Physiological Reports. https://doi.org/10.14814/phy2.70263

Vancouver

Fitze DP, Mair-Noack N, Brun D, Nanz D, Snedeker JG, Spörri J. Shape factor versus truncated cone‐based quantification of quadriceps and hamstring muscle volumes—A choice between accuracy and precision. Physiological Reports. 2025. doi:10.14814/phy2.70263

BibTeX
@article{Fitze2025,
  author = {Fitze, Daniel P and Mair-Noack, Nicola and Brun, Dominik and Nanz, Daniel and Snedeker, Jess G and Spörri, Jörg},
  title = {Shape factor versus truncated cone‐based quantification of quadriceps and hamstring muscle volumes—A choice between accuracy and precision},
  journal = {Physiological Reports},
  year = {2025},
  doi = {10.14814/phy2.70263}
}
Start for free →