Diagnostic Accuracy of Dynamic Ultrasound Indices for Fluid Responsiveness Using Bioreactance as the Reference Method in Shock Patients
Journal of Critical and Intensive Care · 2025
DOI: 10.14744/dcybd.2025.78542 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Critical and Intensive Care, 2025. Verfasst von Pervin Hancı und 1 weiteren Autor:innen.
Abstract (Originalsprache)
Aim
Predicting fluid responsiveness in patients with shock is critical. This study aimed to evaluate the diagnostic accuracy of dynamic ultrasound-derived indices in predicting fluid responsiveness, using bioreactance-based cardiac output monitoring as the reference standard. Study Design: A total of 39 adult patients diagnosed with shock who were receiving mechanical ventilation were included. Hemodynamic parameters were assessed using ultrasound [left ventricular outflow velocity-time integral (LVOT-VTI), respirophasic variability of LVOT-VTI, corrected carotid flow time (cCFT), respirophasic variability of carotid artery peak flow velocity (∆Vpeak), and the inferior vena cava distensibility index (dIVC)] and pulse pressure variation (PPV) via invasive arterial monitoring. The bioreactance-derived stroke volume index change after passive leg elevation (ΔSVI ≥10%) served as the reference standard for fluid responsiveness.
Results
Fluid responsiveness was present in 53.8% of patients according to ΔSVI. LVOT-VTI variability (area under the curve [AUC] 0.847, 95% confidence interval [CI]: 0.726–0.968, sensitivity 85.0%, specificity 66.6%) and PPV (AUC 0.832, 95% CI: 0.679–0.985, sensitivity 94.4%, specificity 70.5%) demonstrated the highest predictive accuracy. Carotid flow variability showed moderate performance (AUC 0.754), while dIVC yielded the lowest diagnostic accuracy (AUC 0.676). A strong correlation was observed between bioreactance-derived cardiac index and LVOT-VTI (r=0.835, p
Zitieren
APA
Hancı, P., & İnal, V. (2025). Diagnostic Accuracy of Dynamic Ultrasound Indices for Fluid Responsiveness Using Bioreactance as the Reference Method in Shock Patients. Journal of Critical and Intensive Care. https://doi.org/10.14744/dcybd.2025.78542
Vancouver
Hancı P, İnal V. Diagnostic Accuracy of Dynamic Ultrasound Indices for Fluid Responsiveness Using Bioreactance as the Reference Method in Shock Patients. Journal of Critical and Intensive Care. 2025. doi:10.14744/dcybd.2025.78542
BibTeX
@article{Hanc2025,
author = {Hancı, Pervin and İnal, Volkan},
title = {Diagnostic Accuracy of Dynamic Ultrasound Indices for Fluid Responsiveness Using Bioreactance as the Reference Method in Shock Patients},
journal = {Journal of Critical and Intensive Care},
year = {2025},
doi = {10.14744/dcybd.2025.78542}
}