Diagnostic Accuracy of Point‐of‐Care Ultrasound in Detecting Nasogastric Tube Placement in Emergency Patients
International Journal of Nursing Practice · 2025-12 · 31 (6)
DOI: 10.1111/ijn.70077 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Nursing Practice, online erschienen am 30.10.2025. Verfasst von Kemal Yilmaz und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Internal Medicine, Ege University Hospital, İzmir, Turkey. Hauptthemen laut MEDLINE: Intubation, Gastrointestinal, Point-of-Care Systems. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 52 Literaturangaben.
Abstract (Originalsprache)
Background
Point‐of‐care ultrasound (POCUS) is used to verify the position of the nasogastric tube as an alternative to conventional methods.
Aim
This study aims to determine the diagnostic accuracy of POCUS in detecting nasogastric tube placement in emergency patients.
Methods
This was a prospective diagnostic accuracy study conducted at an emergency department between August and November 2021. We included 72 consecutively recruited patients aged 18 years and older who were planned for nasogastric tube insertion. The index and reference tests were ultrasound and chest X‐ray, respectively. Nasogastric tube placement was detected by ultrasound and X‐ray methods in all patients. Sensitivity, specificity and predictive values were calculated.
Results
Seventy‐two patients (mean age: 69.49 ± 13.75, 55.6% male) were included. According to neck and gastric ultrasound, 58 nasogastric tubes (80.6%) could be detected. When POCUS was compared to X‐rays, 56 (84.9%) were true positive and two (33.3%) were false positive. Fourteen nasogastric tubes (19.4%) could not be detected. When POCUS was compared to X‐rays, four (66.7%) were true negative and 10 (15.1%) were false negative. A combination of neck and gastric ultrasound had a sensitivity of 84.84% (95% CI, 73.9%–92.49%), a specificity of 66.6% (95% CI, 22.28%–95.67%), a positive predictive value of 96.55% (95% CI, 89.99%–98.87%) and a negative predictive value of 28.57% (95% CI, 15.19%–47.19%). The percentage agreement was high (0.83%), and Gwet's AC1 statistic rated as moderate (AC1 = 0.46).
Conclusion
POCUS can be used as a diagnostic tool in detecting nasogastric tube placement in the stomach but should be confirmed with a chest X‐ray in patients with a negative ultrasound result.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Internal Medicine, Ege University Hospital, İzmir, Turkey.
- Faculty of Health Sciences, Department of Nursing, Izmir Bakircay University, İzmir, Turkey.
- Faculty of Medicine, Department of Emergency Medicine, Ege University, İzmir, Turkey.
ORCID-Profile: Kemal Yilmaz, Elif Günay İsmailoğlu, Funda Karbek Akarca
Zitieren
APA
Yilmaz, K., İsmailoğlu, E. G., & Akarca, F. K. (2025). Diagnostic Accuracy of Point‐of‐Care Ultrasound in Detecting Nasogastric Tube Placement in Emergency Patients. International Journal of Nursing Practice, 31(6). https://doi.org/10.1111/ijn.70077
Vancouver
Yilmaz K, İsmailoğlu EG, Akarca FK. Diagnostic Accuracy of Point‐of‐Care Ultrasound in Detecting Nasogastric Tube Placement in Emergency Patients. International Journal of Nursing Practice. 2025;31(6). doi:10.1111/ijn.70077
BibTeX
@article{Yilmaz2025,
author = {Yilmaz, Kemal and İsmailoğlu, Elif Günay and Akarca, Funda Karbek},
title = {Diagnostic Accuracy of Point‐of‐Care Ultrasound in Detecting Nasogastric Tube Placement in Emergency Patients},
journal = {International Journal of Nursing Practice},
year = {2025},
volume = {31},
number = {6},
doi = {10.1111/ijn.70077}
}
EUVIMED